Gremo1050F4 Instruction manual
5 User manual for GreControl control
5.10
Crane setting
The crane setting window can be accessed by pressing
in the main window.
Fig. 64 GreControl, crane slew settings
Select the function to change values for, followed by its
direction if required. Crane slew has been selected in the
above example, followed by right min. current. Change
with + and - and confirm with
.
The value can be changed until it has been confirmed with
.
In the settings menu you can reset the values to the
factory settings using
followed by
Reset
.
The
button in the top right corner can be used to return
to the main window.
The
button can be used to return to the previous page.
There are four setting values to choose from for a function:
• Min
Current at the lowest output control in milliamperes, the
minimum function speed, is set to put the function just
at the start position but does not move.
• Max
Current at maximum output control in milliamperes,
maximum function speed, is set so full lever extension
corresponds to the desired maximum speed.
• Start
Length of the start ramp in milliseconds. How gentle the
function starts.
91