12 Other equipment and optional equipment
12.3 Fire extinguishing system
Gremo1050F4 Instruction manual
12.3.4
Actions after the fire
• Check that the fire has been properly extinguished. Use
additional extinguishers if necessary.
• Disable main fuse F49 to switch off the alarm.
• Do not start the machine until the cause of the fire has
been established and any faults are rectified. You are
required to observe and follow the instruction signs on
the machine.
• The fire extinguishing system must be inspected once a
year by authorised service personnel. Check this with
your insurance company.
NOTICE
If the fire extinguishing system is triggered or the hand-
held fire extinguisher is used.
As soon as possible, try to wash the machine with the
high pressure washer and an alkaline cleaning agent.
The extinguishing agent contains a salt solution which
corrodes the engine parts and the cleaning agent
removes the binding agent in the extinguishing foam.
12.3.5
Component specification
Fig. 150 Fire extinguishing system, component placement
1.
Extinguishing container
2.
Detector flask
3.
Detector loop
4.
Fire extinguishing loop