GMV5 DC INVERTER VRF UNITS SERVICE MANUAL
6
III. Basic Parameters of Unit
1. Basic Parameters of ODU
Model
GMV-22
4WM/B-
X
GMV-28
0WM/B-
X
GMV-33
5WM/B-
X
GMV-40
0WM/B-
X
GMV-45
0WM/B-
X
GMV-50
4WM/B-
X
GMV-56
0WM/B-
X
GMV-61
5WM/B-
X
Product Code
CN851
W1280
CN851
W1290
CN851
W1300
CN851
W1310
CN851
W1320
CN851
W1610
CN851
W1620
CN851
W1630
Refrigeration
Capacity
HP
8
10
12
14
16
18
20
22
Combination Mode
—
——
——
——
——
——
——
——
——
Power Supply
380-415V 3N~ 50Hz/60Hz
Rated
Capacity
Cooling
kW
22.4
28
33.5
40
45
50.4
56
61.5
Heating
kW
25
31.5
37.5
45
50
56.5
63
69
Dimensions
(W x D x H)
mm
930 x
765 x
1605
930 x
765 x
1605
1340 x
765 x
1605
1340 x
765 x
1605
1340 x
765 x
1605
1340 x
765 x
1740
1340 x
765 x
1740
1340 x
765 x
1740
Tubing
Dimensio
ns
Liquid
Pipe
mm
Φ
9.52
Φ
9.52
Φ
12.7
Φ
12.7
Φ
12.7
Φ
15.9
Φ
15.9
Φ
15.9
Gas
Pipe
mm
Φ
19.05
Φ
22.2
Φ
25.4
Φ
25.4
Φ
28.6
Φ
28.6
Φ
28.6
Φ
28.6
Balanc
e pipe
mm
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Weight
kg
225
225
285
360
360
360
385
385
Refrigera
nt
Name
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
Built-in
Filling
Volume
kg
5.9
6.7
8.2
9.8
10.3
11.3
14.3
14.3
Model
GMV-68
0WM/B-
X
GMV-73
0WM/B-
X
GMV-78
5WM/B-
X
GMV-85
0WM/B-
X
GMV-90
0WM/B-
X
GMV-96
0WM/B-
X
GMV-10
10WM/B
-X
GMV-10
65WM/B
-X
Refrigeration
Capacity
HP
24
26
28
30
32
34
36
38
Combination Mode
—
GMV-28
0WM/B-
X +
GMV-40
0WM/B-
X
GMV-28
0WM/B-
X +
GMV-45
0WM/B-
X
GMV-28
0WM/B-
X +
GMV-50
4WM/B-
X
GMV-28
0WM/B-
X +
GMV-56
0WM/B-
X
GMV-28
0WM/B-
X +
GMV-61
5WM/B-
X
GMV-33
5WM/B-
X +
GMV-61
5WM/B-
X
GMV-40
0WM/B-
X+
GMV-61
5WM/B-
X
GMV-45
0WM/B-
X +
GMV-61
5WM/B-
X
Power Supply
380-415V 3N~ 50Hz/60Hz
Rated
Capacit
y
Cooling
kW
68
73
78.4
84
89.5
95
101.5
106.5
Heating
kW
76.5
81.5
88
94.5
100.5
106.5
114
119
Dimensions (W x D x
H)
mm
930 x
765 x
1605 +
1340 x
765 x
1605
930 x
765 x
1605 +
1340 x
765 x
1605
930x
765 x
1605 +
1340 x
765 x
1740
930x
765 x
1605 +
1340 x
765 x
1740
1930 x
765 x
1605 +
1340 x
765 x
1740
1340 x
765 x
1605+
1340 x
765 x
1740
1340 x
765 x
1605 +
1340 x
765 x
1740
1340 x
765 x
1605 +
1340 x
765 x
1740
Tubing
Dimensio
ns
Liquid
Pipe
mm
Φ
15.9
Φ
19.05
Φ
19.05
Φ
19.05
Φ
19.05
Φ
19.05
Φ
19.05
Φ
19.05
Air Pipe
mm
Φ
28.6
Φ
31.8
Φ
31.8
Φ
31.8
Φ
31.8
Φ
31.8
Φ
38.1
Φ
38.1
Balance
pipe
mm
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Φ
9.52
Weight
kg
225+36
0
225+36
0
225+360
225+38
5
225+38
5
285+385
360+38
5
360+385
Refrigera
nt
Name
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
Built-in
Filling
Volume
kg
6.7+9.8
6.7+10.
3
6.7+11.3
6.7+14.
3
6.7+14.
3
8.2+14.3
9.8+14.
3
10.3+14.
3
Содержание GMV-224WM/B-X
Страница 1: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL T1 R410A 50 60Hz GC201508...
Страница 6: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 3 2 Piping Diagram of GMV 400WM B X and GMV 450WM B X...
Страница 27: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 24...
Страница 29: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 26 V Construction Organization Process...
Страница 38: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 35...
Страница 45: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 42 Part 5 Piping Connection Schematic Diagram of Piping Connection...
Страница 47: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 44 GMV 504WM B X GMV 560WM B X and GMV 615WM B X...
Страница 156: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 153 low press ure air pipe...
Страница 158: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 155 2 Low exhaust temperature protection E2...
Страница 159: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 156 3 System high pressure protection E1 4 System low pressure protection E3...
Страница 160: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 157...
Страница 161: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 158 5 System refrigerant lacking protection U4...
Страница 162: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 159 6 System high pressure ratio protection J8...
Страница 163: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 160 7 System low pressure ratio protection J9...
Страница 165: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 162 11 Pressure sensor fault...
Страница 224: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 221 2 Model GMV 335WM B X Exploded View...
Страница 227: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 224 3 Model GMV 400WM B X GMV 450WM B X Exploded View...
Страница 230: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 227 4 Model GMV 504WM B X GMV 560WM B X GMV 615WM B X Exploded View...
Страница 242: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 239...
Страница 248: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 245 Click Finish...
Страница 250: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 247 Check I accept the terms in the License Agreement and click Next...
Страница 254: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 251 Click Next Installing...
Страница 255: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 252 Click Close...
Страница 272: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 269...
Страница 277: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 274 Power input Gateway Running Alarm Power Address Function...
Страница 287: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 284 1 4 2 5 Communication Debug...
Страница 297: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 294...
Страница 300: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 297 11 In the displayed window select I Agree and click Next to continue...
Страница 304: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 301...
Страница 307: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 304...
Страница 315: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 312 After detection detected devices will be listed in the Net tree...
Страница 349: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 346...
Страница 352: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 349 11 In the displayed window select I Agree and click Next to continue...
Страница 375: ...GMV5 DC INVERTER VRF UNITS SERVICE MANUAL 372 JF00302751...