4.5 Console Type Indoor Unit
Removal of Fan Motor
Remark: before removing, making sure power is disconnected.
Step
Diagram
Operation Procedure
(1) Open the
panel.
Press clasps at both sides to
“OPEN” position.
(2) Remove
filter and
front case.
Remove 5 screws fixing the
front case.
(3) Remove
electric box.
Open electric box cover, loosen
all connection wires and then
remove screws.
(4) Remove
water tray
and swing
motor.
Remove 2 screws fixing water
tray and swing motor
respectively.
(5) Remove
evaporator.
Remove the fixer fixing the
evaporator, press 2 clasps at
left side and then remove the
evaporator.