Johnson Controls Unitary Products

5292154-UIM-A-0317

FULL-CASED UPFLOW/COUNTERFLOW FOR 
COOLING/HEAT PUMPS

MODELS: CF

FULL-CASED MULTI-POSITION FOR 
COOLING/HEAT PUMPS

MODELS: CM

ISO 9001

Certified Quality

Management System

INSTALLATION MANUAL

LIST OF SECTIONS

GENERAL  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COIL INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DIRECT DUCT INSTALLATION (CF MODELS)  . . . . . . . . . . . . . . . . . 5
DUCT CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CONDENSATE DRAIN CONNECTIONS   . . . . . . . . . . . . . . . . . . . . . . 6

REFRIGERANT LINE CONNECTION  . . . . . . . . . . . . . . . . . . . . . . . .  6
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
INSTRUCTING THE OWNER   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
AIR SYSTEM ADJUSTMENT   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
INSTALLATION VERIFICATION  . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

LIST OF FIGURES

Pressure Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Component Location - Cased Coil CF Model . . . . . . . . . . . . . . . . . . . . 2
Component Location - Cased Coil CM Model   . . . . . . . . . . . . . . . . . . . 5
Duct Flanges - Coils CF / CM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Vertical Applications with Furnaces  . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Vertical Applications with Modular Air Handlers . . . . . . . . . . . . . . . . . . 6
Coil Blow Off Wing Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CM Horizontal Right Application with Furnace  . . . . . . . . . . . . . . . . . . . 6
CM Horizontal Left Application with Furnace  . . . . . . . . . . . . . . . . . . . . 7
Diverter Shroud Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CM Horizontal Right Application with Modular Air Handler   . . . . . . . . . 7
CM Horizontal Left Application with Modular Air Handler . . . . . . . . . . . 7
Vapor Line Grommet   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Recommended Distributor Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . 9

Piston Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
TXV Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
TXV Bulb and Equalizer line Installations  . . . . . . . . . . . . . . . . . . . . .  10
Proper Bulb Location for TXV  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
Vertical Temperature Bulb Orientation  . . . . . . . . . . . . . . . . . . . . . . .  11
CM “N” & “A” Coil   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Communicating Port of the ECM Modular Blower Control Board  . . .  12
Communicating Port of the Furnace  . . . . . . . . . . . . . . . . . . . . . . . . .  12
Wiring Diagram - EEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
Drain Traps  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
Location of Coil Trapped and Plugged 
Drain Connections with Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
Location of Coil Trapped and Plugged Drain 
Connections with Modular Air Handler  . . . . . . . . . . . . . . . . . . . . . . .  15

LIST OF TABLES

Dimensions - CF Upflow/Downflow Full Cased Coils . . . . . . . . . . . . . . 2
Dimensions - CM Multi-position Full Cased Coils   . . . . . . . . . . . . . . . . 3
Coil Air Flow Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Air Flow Data - Static Pressure Drop for CM Models  . . . . . . . . . . . .  12
Air Flow Data - Static Pressure Drop for CF Models   . . . . . . . . . . . .  12

SECTION I: GENERAL

This instruction covers the installation of the following coils with fur-
naces or MP / ME / MVC modular air handlers.

The coils have sweat connect fittings. All coils are shipped with a low
psi nitrogen holding charge. See Figures 1.

SECTION II: SAFETY

This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.

Understand and pay particular attention to the signal words 

DANGER

,

WARNING

, or 

CAUTION

DANGER 

indicates an 

imminently

 hazardous situation, which, if not

avoided, 

will result in death or serious injury

WARNING 

indicates a 

potentially

 hazardous situation, which, if not

avoided, 

could result in death or serious injury

.

CAUTION 

indicated a potentially hazardous situation, which, if not

avoided may result in minor or moderate injury. It is also used to alert
against unsafe practices and hazards involving only property damage. 

 WARNING

Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this manual for assis-
tance or additional information, consult a qualified installer or service
agency.

 WARNING

The furnace area must not be used as a broom closet or for any other stor-
age purposes, as a fire hazard may be created. Never store items such as
the following on, near or in contact with the furnace.

1. Spray or aerosol cans, rags, brooms, dust mops, vacuum clean-

ers or other cleaning tools.

2. Soap powders, bleaches, waxes or other Cleaning compounds;

plastic items or containers; gasoline, kerosene, cigarette lighter
fluid, dry cleaning fluids or other volatile fluid.

3. Paint thinners and other painting compounds.
4. Paper bags, boxes or other paper products

Never operate the furnace with the blower door removed. To do so could
result in serious personal injury and/or equipment damage.

!

!

Содержание CF18A

Страница 1: ...ure Drop for CF Models 12 SECTION I GENERAL This instruction covers the installation of the following coils with fur naces or MP ME MVC modular air handlers The coils have sweat connect fittings All coils are shipped with a low psi nitrogen holding charge See Figures 1 SECTION II SAFETY This is a safety alert symbol When you see this symbol on labels or in manuals be alert to the potential for per...

Страница 2: ...HQ UHFHLYHG A0267 001 COIL ACCESS PANEL VERTICAL POSITION SECONDARY DRAIN VERTICAL OR HORIZONTAL POSITION PRIMARY DRAIN HORIZONTAL POSITION SECONDARY DRAIN VAPOR LINE LIQUID LINE LOCATION TABLE 1 Dimensions CF Upflow Downflow Full Cased Coils Models1 1 Asterisk denotes coil model is available as a flex coil or with factory installed TXV Dimensions 2 2 All dimensions are in inches Refrigerant Conne...

Страница 3: ... CM18A 19 1 2 14 1 2 13 1 2 13 1 2 3 8 3 4 CM18B 19 17 1 2 16 1 2 16 1 2 CM24A 19 1 2 14 1 2 13 1 2 13 1 2 CM24B 19 17 1 2 16 1 2 16 1 2 CM24C 21 21 20 20 CM25B 25 5 8 17 1 2 16 1 2 16 1 2 CM30A 25 1 2 14 1 2 13 1 2 13 1 2 CM30B 23 17 1 2 16 1 2 16 1 2 CM30C 23 21 20 20 CM30D 25 24 1 2 23 1 2 23 1 2 CM36A 25 1 2 14 1 2 13 1 2 13 1 2 CM36B 25 5 8 17 1 2 16 1 2 16 1 2 CM36C 25 21 20 20 CM36D 25 24 1...

Страница 4: ...ront of cabinet 2 Remove two screws from top front side of cabinet 3 Remove transition angle rotate angle 180 end for end and secure to top front side of cabinet 4 For installation with modular air handling unit remove the transition angle and discard it FIGURE 3 Component Location Cased Coil CM Model TABLE 3 Coil Air Flow Limits Coil 1 Size 1 Asterisk denotes coils only available with Factory Mou...

Страница 5: ...Drain Connections for further installation instruction Horizontal right conversion CM Models only 1 Remove coil access panel 2 Slide coil drain pan assembly out of coil cabinet 3 Install the front and the back coil blow off wings apply only to N coils in accordance with the following a Locate 4 screws 2 front side and 2 back side securing the coil delta plates to the coil drain pan b Loosen each s...

Страница 6: ... system or filter and will not be exposed to freezing temperatures Instruct the owner that the indoor coil drain pan should be inspected and cleaned regularly to prevent odors and assure proper drainage Coils should be installed level or pitched slightly toward the drain end Suggested pitch should not exceed 1 4 inch per foot of coil Drain plugs can be removed using a standard 3 8 drive socket rat...

Страница 7: ...nd isolated by using appropriate hangers or strapping SECTION VIII COIL METERING DEVICES A piston or a TXV flex coil models is to be installed in the field There is an installation manual that comes with the TXV kit It is recommended to install the piston or TXV kit prior to installation of coil and brazing of line set Until brazing is completed and cooled the TXV sensing bulb must not be installe...

Страница 8: ...the distributor assembly with supplied fittings Ensure Teflon washer is seated in distributor Hand tighten and turn an additional 1 4 turn to seal Do not over tighten fittings See Figure 16 5 Slide the nut removed in step 3 over the supplied liquid line Place supplied Teflon washer from TXV kit in place on TXV and install liq uid line to the top of the thermal expansion valve Adjust assembly so li...

Страница 9: ...ILS Coils equipped with an EEV are available for use with a fully modulating matched system The EEV and controls are factory installed The installer only has to connect the included communication 4 wire cable to the communicating 4 pin connector on the furnace or modular blower control board See Figure 21 22 for connection diagrams and Figure 23 for wiring diagram FIGURE 16 TXV Installation WARNIN...

Страница 10: ... 1 2 203 570 17 FFHVV SDQHO UHPRYHG 1 7 5 1 7 5 9 7521 2 9 35 0 5 5 1 137 9 325 5 5 5 17 1 211 7 21 48 5 5 5 17 1 211 7 21 25 217 5 1 3 1 6 21 5 5 1 25 217 2 1 7 21 3 3 7 5 137 6 21 5 5 1 83 2 137 9 57 5 1 3 1 2 203 570 17 FFHVV SDQHO UHPRYHG 1 7 5 1 7 5 9 7521 2 5217 9 2 2 25 0 02 9 1 225 2 35 6685 75 16 8 5 1 225 2 35 6685 75 16 8 5 FIGURE 21 Communicating Port of the ECM Modular Blower Control ...

Страница 11: ...S ONLY IF ALUMINUM CONDUCTORS ARE PRESENT ALL APPLICABLE LOCAL AND NATIONAL CODES MUST BE FOLLOWED IPT INDOOR COIL PRESSURE TRANSDUCER ITS INDOOR COIL 7 03 5 785 SENSOR EEV ELECTRONIC EXPANSION VALVE 5292155 UWD B 0117 EEV MOTOR PR1 1 T1 GRN RED BLK WHT BLU BLU IPT YEL WHT BLK EEV RED BLU ORG WHT YEL ITS LED INDICATORS EEV CONTROL BOARD A C R B LEGEND EEV CONTROL LED DIAGNOSTIC CODES Control failu...

Страница 12: ...48D 1250 1820 2250 2500 2795 3062 3307 CM49C 690 1150 1420 1630 1820 1990 2150 CM49D 970 1410 1740 2050 2290 2510 2710 CM50C 990 1440 1700 1950 2180 2390 2580 CM50D 940 1470 1890 2170 2430 2660 2870 CM60C 910 1551 1930 1820 2035 2229 2408 CM60D 1220 1730 2140 2440 2728 2988 3228 CM61C 990 1440 1700 1950 2180 2390 2580 CM61D 940 1470 1890 2220 2490 2720 2940 CM64D 970 1540 1800 1940 2169 2376 2566 ...

Страница 13: ... 33 7 21 2 1 2 33 7 21 35 0 5 5 1 75 3 211 7 21 6 21 5 5 1 75 3 211 7 21 5 1 3 8 25 25 217 6 21 5 5 1 0 21 35 0 5 5 1 75 3 211 7 21 2 2 5 7 2 33 7 21 7 2 33 7 21 2 2 5 1 3 8 25 9 57 6 21 5 5 1 851 851 851 851 127 9HULI WKDW DOO GUDLQV DUH WUDSSHG RU SOXJJHG 83 2 33 7 21 2 1 2 33 7 21 5 1 5 2 5 1 5 2 5 7 2 33 7 21 7 2 33 7 21 2 5 1 5 2 5 1 5 25 0 35 0 5 5 1 75 3 211 7 21 6 21 5 5 1 75 3 211 7 21 5 ...

Страница 14: ... change without notice Published in U S A 5292154 UIM A 0317 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes 1187005 UIM G 0816 York International Corp 5005 York Drive Norman OK 73069 NOTES ...

Отзывы: