background image

GREE

Multi Variable Air Conditioners Indoor Unit

192

Exploded View of GMV-ND14PLS/B-T(U) / GMV-ND18PLS/B-T(U)

No.

Name of part

For the following unit

Unit

Product Code

GMV-ND14PLS/B-T(U)

CM810N1690

Part code

Quantity

1

Air Outlet Frame Assy

000141000011

1

2

Evaporator Assy

01100100036201

1

3

Electric Expand Valve Fitting

4304413215

1

4

Strainer

0721200102

1

5

Electronic Expansion Valve

07334466

1

6

Liquid Level Switch

430024000005

1

7

Strainer

07213050

1

8

Water Tray Assy

000069000059

1

9

Water Pump

812007060016

1

10

Pump Drainpipe

200070000005

1

11

Bottom Cover Plate Assy

000133000011

1

12

Hook 2

01344100034

2

13

Left Side Plate Assy

000080060035

1

Содержание CM100N1480

Страница 1: ...Multi Variable Air Conditioners Indoor Units GC201912 IX Capacity 5600Btu h 96000Btu h Rated Frequency 60 Hz...

Страница 2: ...harge Compact Cassette Type Indoor Unit 8 2 Nomenclature 8 3 Product Features 9 3 1 Features of Low Static Pressure Duct Type Indoor Unit 9 3 2 Features of Slim Duct Type Indoor Unit 9 3 3 Features of...

Страница 3: ...Duct Type Indoor Unit 41 4 16 360 Air Discharge Compact Cassette Type Indoor Unit 42 CONTROL 45 CHAPTER 2 CONTROL 46 1 Operation Flowchart 46 2 Wired Controller 47 2 1 Control Panel 47 2 2 Installati...

Страница 4: ...of Floor Ceiling Type Indoor Unit 108 3 9 Installation of Fresh Air Processing Indoor Unit 110 3 10 Installation of Compact Four way Cassette Type Indoor Unit 112 3 11 Installation of Super High Stati...

Страница 5: ...12 Air Handler type Indoor Unit 157 3 13 AHU KIT 158 3 14 1 way Cassette Type Indoor Unit 158 3 15 Low Static Pressure Duct Type Indoor Unit 159 3 16 360 Air Discharge Compact Casssette Type Indoor Un...

Страница 6: ...Ceiling Type Indoor Unit 209 5 7 Fresh Air Processing Type Indoor Unit 218 5 8 Console Type Indoor Unit 221 5 9 Wall Mounted type Indoor Unit 223 5 10 Compact Four way Cassette Type Indoor Unit 234 5...

Страница 7: ...GREE Multi Variable Air Conditioners Indoor Unit 1 PRODUCT...

Страница 8: ...V 60Hz R410A GMV ND07PLS B T U CM810N1720 2 2 7500 2 8 8500 GMV ND09PLS B T U CM810N1710 2 8 9500 3 2 10500 GMV ND12PLS B T U CM810N1700 3 6 12000 4 0 13500 GMV ND14PLS B T U CM810N1690 4 0 15000 4 5...

Страница 9: ...500 2 5 8500 208 230V 60Hz R410A GMV N09G E3A D U CM100N2340 2 8 9500 3 2 11000 GMV N12G E3A D U CM100N2350 3 5 12000 4 0 13500 GMV N18G E3A D U CM100N2360 5 2 18000 5 8 20000 GMV N24G E3A D U CM100N2...

Страница 10: ...9 20000 208 230V 60Hz R410A GMV ND24PHS A T U CM810N0150 7 0 24000 7 9 27000 GMV ND30PHS A T U CM810N0160 8 8 30000 10 0 34000 GMV ND36PHS A T U CM810N0170 10 6 36000 11 7 40000 GMV ND42PHS A T U CM8...

Страница 11: ...ir Processing Type Indoor Unit Model Product Code Cooling Capacity Heating Capacity Power Supply Refrigerant Appearance kW Btu h kW Btu h GMV NDX42P A T U CM810N1250 12 3 42000 8 5 29000 208 230V 60Hz...

Страница 12: ...0 10 6 36000 11 7 40000 GMV ND42PHS B T U CM810N0750 12 3 42000 13 8 47000 GMV ND48PHS B T U CM810N0820 14 1 48000 15 0 54000 GMV ND54PHS B T U CM810N0760 15 8 54000 17 6 60000 GMV ND72PH B T U CM810N...

Страница 13: ...Type Indoor Unit Model Product Code Cooling Capacity Heating Capacity Power Supply Refrigerant Appearance kW Btu h kW Btu h GMV ND07TD A T U CM502N0151 2 2 7500 2 5 8500 208 230V 60Hz R410A GMV ND09TD...

Страница 14: ...motor 4 Function code X fresh air W double thermal source 5 Cooling capacity air volume code Indoor unit nominal cooling capacity 1000 Btu h All heat exchanger air volume 100 m3 h 6 Unit type PL low...

Страница 15: ...of evaporator Slim Small The unit is only 200mm s thick and 450 mm s deep Suspended ceiling doesn t have to be very high It is suitable for ordinary rooms Wiring of Electric Control Box Mounting board...

Страница 16: ...height difference up to 1 0m which can effectively drain out condensing water and save space 3 4 Features of Wall Mounted Type Indoor Unit Filter can be cleaned The filter is removable and can be cle...

Страница 17: ...High static pressure design Static pressure can be up to 150Pa especially suitable for places in need of long distance airflow Convenient installation You can choose circular air duct or rectangular...

Страница 18: ...ely DC inverter technology adopted constant humidity is enabled with less power consumption Integrated system control with Gree GMV Multi VRF System Air conditioning and fresh air two in one Less inve...

Страница 19: ...motor Ultra low noise operation DC inverter motor can realize stepless speed regulation to lower noise Indoor unit can be set to work under auto quiet mode via wired controller Protection function Ant...

Страница 20: ...uitable for rooms of compact structure or small installation space Also it provides you with a comfortable and quiet living environment Convenient installation Tab type plastic filter detachable fan m...

Страница 21: ...16 24 3 16 7 7 8 27 9 16 24 3 16 7 7 8 Packaging Mm 893 743 305 893 743 305 893 743 305 inch 35 3 16 29 1 4 12 35 3 16 29 1 4 12 35 3 16 29 1 4 12 Net Weight lbs 51 51 51 Kg 23 23 23 Gross Weight lbs...

Страница 22: ...ss Weight lbs 73 86 86 kg 33 39 39 Pipe Connection Liquid Side mm 6 35 9 52 9 52 inch 1 4 3 8 3 8 Gas Side mm 12 7 15 9 15 9 inch 1 2 5 8 5 8 Drain Pipe mm 25 25 25 inch 1 1 1 Power Supply 1 phase 208...

Страница 23: ...lbs 41 41 41 42 kg 18 5 18 5 18 5 19 Gross Weight lbs 52 52 52 53 kg 23 5 23 5 23 5 24 Pipe Connection Liquid Side mm 6 35 6 35 6 35 6 35 inch 1 4 1 4 1 4 1 4 Gas Side mm 9 52 9 52 9 52 12 7 inch 3 8...

Страница 24: ...5 25 31 Gross Weight lbs 68 68 83 kg 31 31 37 5 Pipe Connection Liquid Side mm 6 35 9 52 9 52 inch 1 4 3 8 3 8 Gas Side mm 12 7 15 9 15 9 inch 1 2 5 8 5 8 Drain Pipe mm 25 25 25 inch 1 1 1 Power suppl...

Страница 25: ...8 133 inch 40 11 16 40 7 8 5 1 4 40 11 16 40 7 8 5 1 4 40 11 16 40 7 8 5 1 4 40 11 16 40 7 8 5 1 4 40 11 16 40 7 8 5 1 4 Net Weigh Main Body lbs 50 58 58 58 58 kg 22 5 26 5 26 5 26 5 26 5 Panel lbs 15...

Страница 26: ...50 65 950 950 65 950 950 65 inch 37 3 8 37 3 8 2 1 2 37 3 8 37 3 8 2 1 2 37 3 8 37 3 8 2 1 2 37 3 8 37 3 8 2 1 2 37 3 8 37 3 8 2 1 2 Panel Packaging mm 1033 1038 133 1033 1038 133 1033 1038 133 1033 1...

Страница 27: ...1 16 10 13 16 37 7 7 8 11 3 4 37 7 7 8 11 3 4 37 7 7 8 11 3 4 Packaging mm 973 258 370 973 258 370 1068 288 395 1068 288 395 1131 398 328 inch 38 5 16 10 3 16 14 9 16 38 5 16 10 3 16 14 9 16 42 1 16 1...

Страница 28: ...6 35 6 35 9 52 inch 1 4 1 4 1 4 1 4 3 8 Gas Side mm 9 52 9 52 12 7 12 7 15 9 inch 3 8 3 8 1 2 1 2 5 8 Drain Pipe mm 20 20 20 20 30 inch 4 5 4 5 4 5 4 5 1 1 6 Power supply 1 phase 208 230V 60Hz Fan Typ...

Страница 29: ...ing Mechanism Direct driven Motor Type BLDC Motor Power Input W 20 20 20 25 35 Motor Running Current A 0 1 0 1 0 1 0 12 0 17 Airflow Rate H M L CFM 294 259 177 294 259 177 294 259 177 371 271 188 500...

Страница 30: ...lm hydrophilic film Air Filter PP PP MD10 Insulation Material Foamed polystyrene Refrigeration Control Device EXV Protection Device Fuse 4 5 Console Type Indoor Unit Model GMV ND07C A T U GMV ND09C A...

Страница 31: ...0 Cooling Capacity Btu h 18000 24000 30000 36000 42000 48000 kW 5 3 7 0 8 8 10 6 12 3 14 1 Heating Capacity Btu h 20000 27000 34000 40000 47000 54000 kW 5 9 7 9 10 11 7 13 8 15 8 Casing Finish Galvani...

Страница 32: ...0 0 4 0 0 4 0 0 4 0 0 4 0 0 4 Pa 0 100 0 100 0 100 0 100 0 100 0 100 Sound Pressure Level H M L dB A 44 40 36 45 41 37 46 44 42 46 44 42 48 45 42 48 46 44 Heat Exchanger Fenestrate plain film hydroph...

Страница 33: ...00 kW 2 8 3 5 4 4 5 3 7 Heating Capacity Btu h 10500 13500 17000 20000 27000 kW 3 1 4 0 5 5 9 7 9 Casing Finish Galvanized Steel plate Dimensions W D H Body Outline mm 1200 520 340 1200 520 340 1200 5...

Страница 34: ...ter PP Insulation Material Foamed polystyrene Refrigeration Control Device EXV Protection Device Fuse Panel name TE01 TE01 TE01 TE01 TE01 4 8 Floor Ceiling Type Indoor Unit Model GMV ND09ZD A T U GMV...

Страница 35: ...3 14 1 Heating Capacity Btu h 33000 40000 47000 54000 kW 10 0 11 7 13 8 15 8 Casing Finish Galvanized Steel plate Dimensions W D H Outline mm 1420 700 245 1700 700 245 1700 700 245 1700 700 245 inch...

Страница 36: ...300 1400 700 300 1483 791 385 inch 55 1 8 27 9 16 11 13 16 55 1 8 27 9 16 11 13 16 58 3 8 31 1 8 15 3 16 Packaging mm 1601 813 365 1601 813 365 1578 883 472 inch 63 32 14 3 8 63 32 14 3 8 62 1 8 34 3...

Страница 37: ...472 1578 883 472 inch 62 1 8 34 3 4 18 5 8 62 1 8 34 3 4 18 5 8 Net Weight lbs 181 181 kg 82 82 Gross Weight lbs 229 229 kg 104 104 Pipe Connection Liquid Side mm 9 52 9 52 inch 3 8 3 8 Gas Side mm 1...

Страница 38: ...000 20000 kW 2 5 3 1 4 0 5 0 5 9 Casing Finish Galvanized Steel plate Dimensions W D H Body Outline mm 596 596 240 596 596 240 596 596 240 596 596 240 596 596 240 inch 23 1 2 23 1 2 9 1 2 23 1 2 23 1...

Страница 39: ...810N0830 CM810N0790 CM810N0800 CM810N0770 Cooling Capacity Btu h 7500 9500 12000 15000 kW 2 2 2 8 3 5 4 4 Heating Capacity Btu h 8500 10500 13500 17000 kW 2 5 3 1 4 5 Casing Finish Galvanized Steel pl...

Страница 40: ...7 16 32 14 3 16 47 7 16 32 14 3 16 47 7 16 32 14 3 16 63 1 16 32 x14 3 8 Net Weight lbs 94 94 94 121 kg 42 6 42 6 42 6 55 Gross Weight lbs 108 108 108 137 kg 49 49 49 62 Pipe Connections Liquid Side...

Страница 41: ...nnections Liquid Side mm 9 52 9 52 9 52 9 52 inch 3 8 3 8 3 8 3 8 Gas Side mm 15 9 15 9 15 9 19 05 inch 5 8 5 8 5 8 3 4 Drain Pipe mm 25 25 25 25 inch 1 1 1 1 Power supply 1 phase 208 230V 60Hz Fan Ty...

Страница 42: ...iquid Side mm 9 52 9 52 inch 3 8 3 8 Gas Side mm 19 05 22 2 inch 3 4 7 8 Drain Pipe mm 25 25 inch 1 1 Power Supply 1 phase 208 230V 60Hz Fan Type Quantity Centrifugal 2 Centrifugal 2 Driving Mechanism...

Страница 43: ...8 58 61 61 61 Pipe Connections Liquid Side mm 6 35 6 35 9 52 9 52 9 52 inch 1 4 1 4 3 8 3 8 3 8 Gas Side mm 9 52 12 7 15 9 15 9 15 9 inch 3 8 1 2 5 8 5 8 5 8 Drain Pipe G1 G1 G1 G1 G1 Power Supply 1 p...

Страница 44: ...uid Side mm 9 52 9 52 9 52 9 52 inch 3 8 3 8 3 8 3 8 Gas Side mm 15 9 15 9 15 9 15 9 inch 5 8 5 8 5 8 5 8 Drain Pipe G1 G1 G1 G1 Power Supply 1 phase 208 230V 60Hz Fan Type Quantity Centrifugal 1 Cent...

Страница 45: ...zing Connection Brazing Connection Brazing Connection Outline Dimension W D H EXV Box mm 203 326 85 203 326 85 203 326 85 inch 8 12 7 8 3 3 8 8 12 7 8 3 3 8 8 12 7 8 3 3 8 Control Box mm 334 284 111 3...

Страница 46: ...Weight kg 9 5 13 lbs 21 29 4 14 1 way Cassette Type Indoor Unit Model GMV ND07TD A T U GMV ND09TD A T U GMV ND12TD A T U Product Code CM502N0151 CM502N0161 CM502N0181 Cooling Capacity Btu h 7500 9500...

Страница 47: ...Device Fuse Fuse Fuse Panel Name TD01 TD01 TD01 4 15 Low Static Pressure Duct Type Indoor Unit Model GMV ND30PLS C T U GMV ND36PLS C T U GMV ND42PLS C T U GMV ND48PLS C T U Product Code CM810N2020 CM8...

Страница 48: ...use 4 16 360 Air Discharge Compact Cassette Type Indoor Unit Model GMV ND05T E T U GMV ND07T E T U GMV ND09T E T U Product Code CM500N1600 CM500N1590 CM500N1620 Cooling Capacity Btu h 5600 7500 9500 k...

Страница 49: ...ontrol Device EXV EXV EXV Protection Device Fuse Fuse Fuse Panel Name TF05 TF05 TF05 Model GMV ND12T E T U GMV ND15T E T U GMV ND18T E T U Product Code CM500N1580 CM500N1610 CM500N1570 Cooling Capacit...

Страница 50: ...echanism Direct driven Direct driven Direct driven Motor Type BLDC BLDC BLDC Motor Power Input W 46 46 46 Motor Running Current A 0 4 0 4 0 4 Airflow Rate H M L CFM 365 325 280 430 385 330 430 385 330...

Страница 51: ...GREE Multi Variable Air Conditioners Indoor Unit 45 CONTROL...

Страница 52: ...GREE Multi Variable Air Conditioners Indoor Unit 46 CHAPTER 2 CONTROL 1 Operation Flowchart...

Страница 53: ...GREE Multi Variable Air Conditioners Indoor Unit 47 2 Wired Controller 2 1 Control Panel 2 1 1 XK46 Wired Controller Fig 2 1 1 Appearance of wired controller Fig 2 1 2 LED graphics of wired controller...

Страница 54: ...sh Air Indoor Unit then the temperature zone will display FAP 6 Cooling mode 7 Dry mode 8 Fan mode 9 Heating mode 10 When inquiring or setting project number of indoor unit it displays NO icon 11 Floo...

Страница 55: ...its 32 Save status of indoor unit 33 It indicates the current wired controller is the slave wired controller address of wired controller is 02 34 Memory status The indoor unit resumes the original set...

Страница 56: ...dium speed medium high speed high speed and turbo status 6 MODE Switch Auto Cooling Dry Fan Heating Floor Heating 3D Heating and Space Heating modes for indoor unit NOTICE The Floor Heating 3D Heating...

Страница 57: ...9 It shows the setting temperature value In case the wired controller is controlling a Fresh Air Indoor Unit then the temperature zone will display FAP 10 Floor Heating mode When Heating and Floor Hea...

Страница 58: ...mode upper limit of system capacitor less 100 remote Save status 30 Allow auxiliary electric heating On icon 31 Reserved function 32 One wired controller controls multiple indoor units 33 Outdoor unit...

Страница 59: ...w up when the unit has those functions 5 FUNCTION Switch among Air Quiet Light Health Absence Save Clean E heater and X fan functions 6 FAN Switch among auto low speed low medium speed medium speed me...

Страница 60: ...rough the shape hole at the rear side of Soleplate of wired controller 3 Stick the bottom plate of wired controller on the wall and then use Self tapping Screw ST3 9 25 MA to fix Soleplate and install...

Страница 61: ...by screws 5 Gate control wiring notice A Factory default provided with Gate control function factory default the DIP switch S1 to ON side B If the gate control system is not involved open the inner sh...

Страница 62: ...e wiring buckle the outer shell and the panel together 2 2 3 Removal Method 1 Wired Controller XK46 Disassembly diagram 1 2 3 4 Fig 2 2 5 Disassembly diagram of wired controller XK46 2 Wired Controlle...

Страница 63: ...E Multi Variable Air Conditioners Indoor Unit 57 Fig 2 2 9 One wired controller controls multiple indoor units simultaneously Fig 2 2 10 Two wired controllers control multiple indoor units simultaneou...

Страница 64: ...rbo function 3 MODE Set operation mode 4 Set up down swing status 5 I FEEL Set I FEEL function 6 TEMP Switch temperature displaying type on the unit s display 7 Set health function and air function 8...

Страница 65: ...ration mode 5 Set quiet function 6 Set health function and air function 7 Set left right swing status 8 Set up down swing status 9 X FAN Set X FAN function 10 TIMER ON Set timer on function 11 TIMER O...

Страница 66: ...ser parameter query 4 User parameter settings 5 Engineering parameter query 6 Engineering parameter settings Engineering application functions can be operated through the IDU wired controller XK46 XK4...

Страница 67: ...s till P10 is displayed on the temperature area Step 4 Press the MODE button to set the parameter to 01 and then Press the ENTER button If the setting is successful MASTER on the wired controller will...

Страница 68: ...cate the IDU especially for the IDU without any LED panel because it cannot display its project number 2 Project number query of IDUs in the entire communication network Press and hold the FUNCTION bu...

Страница 69: ...conflict C5 fault project number of the current IDU project numbers are arranged from small to large Special operations After users press the MODE button to enter project number query the buzzer of t...

Страница 70: ...us to cancel the project number display The method for cancelling the project number display on any wired controller in the network is the same as Display mode Temperature area displays the SN of the...

Страница 71: ...e master slave status of the current IDU 01 sets the current IDU to master IDU 00 After the IDU connected with the current wired controller is successfully set to master IDU MASTER on the wired contro...

Страница 72: ...00 P34 Repeating validity for time point timing 00 single timing 01 repeated everyday 00 This setting is valid only when the timer function is set to time point timing P37 Cooling setting temperature...

Страница 73: ...ss and hold the FUNCTION button for five seconds to enter the engineering parameter query interface The temperature area displays C00 and View is on 1 Within five seconds after C00 is displayed contin...

Страница 74: ...ature sensor of IDU 9 to 99 Operation method In C14 status press the MODE button to enter inlet tube temperature sensor query of IDU Press or to switch the IDU SN Display mode Temperature area display...

Страница 75: ...ller the opening degree of electronic expansion valve of the IDU that has the minimum project number in the HBS network is displayed by default n2 Capacity configuration ratio upper limit of outdoor I...

Страница 76: ...ame Unit 01 Outdoor environment temperature C F 02 Operation frequency of compressor 1 Hz 03 Operation frequency of compressor 2 Hz 04 Operation frequency of outdoor fan Hz 05 Module high pressure C F...

Страница 77: ...number bar code The following is an example Example Temper ature Area Timer Area Remark 1 Remark 2 Entire unit bar code of IDU N1r0128150066 Un to the right n in the middle It indicates that the foll...

Страница 78: ...4 4 The engineering parameter setting list is as follows Table 4 4 Engineering Parameter Setting List Parameter Code Parameter Name Parameter Range Default Value Remark P15 Power down memory mode 00...

Страница 79: ...d 01 valid 00 Select 01 and then press and hold the ENTER CANCEL button to restore the factory settings for user functions factory setting recovery fails if remote shielding is valid P36 Factory setti...

Страница 80: ...dual heat source 01 cancel the setting of dual heat source for the indoor unit 02 set the indoor unit as dual heat source 03 cancel the setting of dual heat source for all units 04 set all units as d...

Страница 81: ...power off the unit and ask for professional maintenance personnel for help The following figure shows the power on high pressure protection fault interface Power on High pressure Protection Fault Inte...

Страница 82: ...will be on Method 2 Step 1 In power on or power off status press and hold the MODE button and SWING simultaneously for five seconds to enter the parameter query interface Step 2 In C00 status press an...

Страница 83: ...n to switch to parameter value settings The parameter value blinks Adjust the parameter value by pressing or and then press the SWING button to complete settings 3 Press the SWING button to return to...

Страница 84: ...0 2 Select a parameter code by pressing or Press the MODE button to switch to parameter value settings The parameter value blinks Adjust the parameter value by pressing or and then press the SWING but...

Страница 85: ...it is MASTER on the wired controller will be on Otherwise repeat steps 1 and 2 In power off status Press MODE for 5 seconds MASTER is on when the master indoor unit is successfully set Method 2 Step...

Страница 86: ...ction of SWING ENTER on the XK79 wired controller is equivalent to the function of ENTER CANCEL on the XK46 wired controller 4 3 3 User Parameter Settings User parameters can be set in power on or pow...

Страница 87: ...he parameter value blinks Adjust the parameter value by pressing or and then press the SWING CANCEL button to complete settings 3 Press the SWING CANCEL button to return to the upper level menu till q...

Страница 88: ...up down swing status 9 X FAN Set X FAN function 10 TIMER ON Set timer on function 11 TIMER OFF Set timer off function 12 SAVE Set energy saving function 13 SLEEP Set sleep function 14 LIGHT Set light...

Страница 89: ...mer area displays query sub items it indicates that there are level 2 query menus Press 5 to enter level 2 query menu selection The content blinks in the timer area Press to switch query sub items and...

Страница 90: ...Press and hold for five seconds to enter the parameter setting status The setting text is displayed and P00 blinks in the temperature area 2 Press to switch the setting code and select a unit paramet...

Страница 91: ...pe 1 03 04 05 06 07 Type 2 01 02 03 04 05 06 07 08 09 P31 High ceiling installation settings 00 standard ceiling installation height 01 high ceiling installation height P32 Capacity adjustment functio...

Страница 92: ...accumulated operating time is added by 400 hours when the second digit is increased by 1 When the second digit is 9 the accumulated operating time is 5000 hours Heavy pollution The first digit is 3 If...

Страница 93: ...n 3 MODE Set operation mode 4 Set up down swing status 5 I FEEL Set I FEEL function 6 TEMP Switch temperature displaying type on the unit s display 7 Set health function and air function 8 LIGHT Set l...

Страница 94: ...nuously within 5 seconds and then the IDU light board will display its project number Exit query 1 After entering query status press Light button for 5 times continuously within 5 seconds to exit quer...

Страница 95: ...GREE Multi Variable Air Conditioners Indoor Unit 89 INSTALLATION...

Страница 96: ...locked air conditioning performance is reduced compressor wear is increased or even hinder the normal operation of the system and burn the compressor 3 The vacuum degree in the refrigerant pipe is ins...

Страница 97: ...lt to be maintained unit exhaust is not smooth which reduces the heat exchanging performance or even prevent the system from normal operation in addition the cold and hot air for heat exchange and the...

Страница 98: ...gs or adhesive tapes 2 2 Condensate Water Pipe 1 Pipes that can be used for air conditioner drainage include water supplying UPVC pipe PP R pipe PP C pipe and HDG steel pipe 2 All relevant certificate...

Страница 99: ...e twisted together 3 If unit is installed in places with intense magnetic field or strong interference it is necessary to use shielded wire Communication cable selection for IDU and wired controller M...

Страница 100: ...wing table lists the detailed dimensions Unit mm inch Item Model A B C D E F G H I GMV ND07PLS A T U GMV ND09PLS A T U GMV ND12PLS A T U 742 29 3 16 491 19 5 16 700 27 1 2 615 24 1 4 200 7 7 8 121 4 3...

Страница 101: ...easures to reduce noise and vibration 5 Electrical installation of unit All electrical installation must be done by professionals according to national and local laws and regulations The unit must be...

Страница 102: ...8 200 17 7 8 462 18 3 16 486 19 2 16 GMV ND14 18PLS B T U 1060 41 3 4 415 16 3 8 1010 39 3 4 200 17 7 8 462 18 3 16 486 19 2 16 GMV ND24PLS B T U 1360 53 1 2 415 16 3 8 1310 51 3 4 200 17 7 8 462 18 3...

Страница 103: ...d reliably Please connect wire according to the wiring diagram on the unit 3 2 4 Selection of Air Switch and Power Cord Model Power Cord Size Air Switch apacity A Minimum Sectional Area of Ground Wire...

Страница 104: ...nsions and Installation and Maintenance Spaces 1500 59 2500 98 3 8 20 3 4 1500 59 Unit mm inch Model A B C D E G H GMV ND07T A T U 950 37 3 8 890 35 840 33 680 26 3 4 780 30 3 4 65 2 1 2 210 8 1 4 GMV...

Страница 105: ...ir conditioner unit is moved to other place The unit shall be installed in accordance with national standards or local regulations Only qualified personnel can carry out installation work please conta...

Страница 106: ...GMV N12G A3A D U GMV N18G A3A D U GMV N12G E3A D U GMV N18G E3A D U 940 37 298 11 3 4 200 7 7 8 GMV N24G A3A D U GMV N24G E3A D U 1008 39 11 16 319 12 9 16 221 8 11 16 GMV ND06G B4B T U GMV ND07G B4B...

Страница 107: ...2 Water can be drained from drainage pipe conveniently 3 Keep the unit from fire flammable objects corrosive gap or exhaust gas 4 There can t be any obstacle at air inlet and air outlet to in order to...

Страница 108: ...Conditioners Indoor Unit 102 3 5 Installation of Console Type Indoor Unit 3 5 1 Outline and Installation Dimension Unit mm inch Location for securing the installation pane Schematic drawing of hooks 3...

Страница 109: ...5 4 Electrical Installation of Unit Live the sensor securing plate remove the front metal plate cover and connect the wire to the terminal board 1 Open the cover of electric box of indoor unit 2 Lead...

Страница 110: ...city A GMV ND07C A T U 208 230V 60Hz 6 GMV ND09C A T U 208 230V 60Hz 6 GMV ND12C A T U 208 230V 60Hz 6 GMV ND18C A T U 208 230V 60Hz 6 3 6 Installation of High Static Pressure Duct Type Indoor Unit 3...

Страница 111: ...is applicable for units with the cooling capacity 72 96 kBtu h C I E H F B D A G Below are dimensions of A B C etc for different models Unit mm inch Model A B C D E F G H I GMV ND72PH A T U 1353 53 1...

Страница 112: ...performance so do not install the unit by yourself Please contact local dealer to arrange professional technicians for the installation Do not connect power until all installation work is finished If...

Страница 113: ...mm inch Model Indoor unit A Suspension bolt pitch B Ceiling opening C Decoration panel D GMV ND09TS A T U 1200 47 1 4 1252 49 5 16 1403 55 1 4 1443 56 13 16 GMV ND12TS A T U GMV ND15TS A T U 1200 47...

Страница 114: ...be installed in accordance with national standards or local regulations Only qualified personnel can carry out installation work please contact with local dealer before installation Make sure all the...

Страница 115: ...1500 59 200 7 7 8 2300 90 1 2 600 23 5 8 600 23 5 8 3 8 3 Installation Notice The unit shall be installed by the professional personnel according to this installation instruction to ensure proper use...

Страница 116: ...24ZD A T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND30ZD A T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND36ZD A T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND42ZD A T U 208 230V 60Hz 15 1 0 AWG18...

Страница 117: ...6 GMV NDX72P A T U 1353 53 1 4 632 24 7 8 992 39 1150 45 1 4 192 7 1 2 327 12 7 8 1483 58 3 8 791 31 1 8 385 15 3 16 GMV NDX96P A T U 1353 53 1 4 632 24 7 8 992 39 1150 45 1 4 192 7 1 2 327 12 7 8 148...

Страница 118: ...the air conditioner unit is moved to other place 3 9 4 Selection of Air Switch and Power Cord Model Power Cord Size Air Switch apacity A Minimum Sectional Area of Ground Wire mm2 AWG Minimum Sectional...

Страница 119: ...er the professional personnel when the air conditioner unit is moved to other place The unit shall be installed in accordance with national standards or local regulations Only qualified personnel can...

Страница 120: ...E F G GMV ND07 09PHS B T U 740 29 1 8 500 19 11 16 830 32 11 16 300 11 13 16 754 29 11 16 700 27 9 16 700 27 9 16 GMV ND12 24PHS B T U 1040 40 15 16 500 19 11 16 1130 44 31 64 300 11 13 16 754 29 11 1...

Страница 121: ...E F B C D G Below are dimensions of A B C etc for different models Unit mm inch Model A B C D E F G GMV ND72 96PH B T U 1240 48 3 4 1452 57 1 8 1280 50 3 8 940 38 1040 41 1071 42 1 8 470 18 1 2 3 11...

Страница 122: ...of the inconvenience of the business contact It should be guided under the professional personnel when the air conditioner unit is moved to other place Installation of the unit must be in accordance...

Страница 123: ...0 AWG18 GMV ND30PHS B T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND36PHS B T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND42PHS B T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND48PHS B T U 208 230V...

Страница 124: ...installing in an area directly over a finished ceiling such as an attic an emergency drain pan is required directly under the unit See local and state codes for requirements When installing this unit...

Страница 125: ...GMV ND24A A T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND30A A T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND36A A T U 208 230V 60Hz 15 1 0 AWG18 1 0 AWG18 GMV ND42A A T U 208 230V 60Hz 15 1 0 AWG1...

Страница 126: ...GMV N12U A T U GMV N24U A T U GMV N48U A T U GMV N96U A T U Unit mm inch 4 6 4 12 200 7 7 8 203 8 150 6 290 11 7 16 250 9 7 8 326 12 7 8 85 3 3 8 40 1 4 7 174 6 7 8 Size of EXV box for GMV N192U A T...

Страница 127: ...intenance space of EXV box Unit mm inch 3 13 2 Installation notice The EXV box can be installed inside and outside The control box should be installed inside Do not install the EXV box in or on the ou...

Страница 128: ...kept Make sure the electronic expansion valve is installed in an upright position 3 13 3 Selection of air switch and power cord Model Power Supply Circuit Breaker Capacity A Minimum Sectional Area of...

Страница 129: ...dealt with on time because of the inconvenience of the business contact It should be guided under the professional personnel when the air conditioner unit is moved to other place The unit shall be ins...

Страница 130: ...for units with the cooling capacity ranging from 30kBtu h to 48kBtu h The following table lists the detailed dimensions Unit mm inch Item Model A B C D E F G H I GMV ND30PLS C T U GMV ND36PLS C T U GM...

Страница 131: ...e and vibration 5 Electrical installation of unit All electrical installation must be done by professionals according to national and local laws and regulations The unit must be grounded reliably Plea...

Страница 132: ...er use Please contact the local Gree appointed service center before installation Any malfunction caused by the unit that is not installed by the Gree appointed service center would probably not be de...

Страница 133: ...ort it Radius of bending parts should be over 200mm 8inch Note that pipes cannot be repeatedly bent or stretched otherwise the material will get harder Do not bend or stretch the pipe for more than 3...

Страница 134: ...ck sound Hold the handle of wrench and make it at right angle to the pipe as in Fig 4 5 1 Use sponge to wrap the un insulated connection pipe and joint Then tie the sponge tightly with plastic tape 2...

Страница 135: ...hloride pipe joint to the drain hose connected to the indoor unit use a commercially available hard vinyl chloride pipe joint nominal diameter 13mm 1 2 inch Drain hose connected to the indoor unit Com...

Страница 136: ...nstallation of water trap shall consider easy cleaning in the future Connection of drainage branch pipe to the standpipe or horizontal pipe of drainage main pipe The horizontal pipe cannot be connecte...

Страница 137: ...t take the cassette type unit for example Unit mm inch 5 3 Precautions When Doing Riser Piping Work 1 Make sure that heat insulation work is executed on the following 2 spots to prevent any possible w...

Страница 138: ...amaged power cord and connecting wire with special flexible wire The earthing shall be reliable and connected to the special earthing device on the construction The installation must be done by specia...

Страница 139: ...GREE Multi Variable Air Conditioners Indoor Unit 133 MAINTENANCE...

Страница 140: ...r Temperature Sensor Error L8 Power Insufficiency Protection d7 Humidity Sensor Error C0 Communication Error L9 Quantity Of Group Control Indoor Units Setting Error d8 Water Temperature Error AJ Filte...

Страница 141: ...normal Replace main control board directly Troubleshooting Replace main control board directly 1 3 2 d3 Ambient temperature sensor error Error display IDU wired controller and IDU receive light board...

Страница 142: ...continuously report the error Possible reason Poor contact between inlet pipe temperature sensor and terminal in mainboard interface Inlet pipe temperature sensor is abnormal Detecting circuit is abn...

Страница 143: ...lay IDU wired controller and IDU receive light board will display Error judgment condition and method Sample the AD value of temperature sensor through temperature sensor detecting circuit and judge t...

Страница 144: ...ay Error judgment condition and method Possible reason If jumper cap model doesn t match with mainboard report the error Jumper cap is not installed Jumper cap model is wrong Detecting circuit is abno...

Страница 145: ...ard error Error display IDU wired controller and IDU receive light board will display Error judgment condition and method Wired controller IIC communication is abnormal Possible reason Communication o...

Страница 146: ...controller and IDU receive light board will display Error judgment condition and method Sample the AD value of temperature sensor through temperature sensor detecting circuit and judge the range of A...

Страница 147: ...t means the unit is under debugging status and the IDU cannot be operated Troubleshooting Possible reason 1 3 12 L1 Indoor fan protection Error display IDU wired controller and IDU receive light board...

Страница 148: ...ulti Variable Air Conditioners Indoor Unit 142 Troubleshooting 1 3 13 L3 Water full protection Error display IDU wired controller and IDU receive light board will display Error judgment condition and...

Страница 149: ...he status of IDU float switch When water level is too high float switch is activated so water full protection happens Possible reason IDU is installed improperly Drainage pump is broken Float switch o...

Страница 150: ...er supply conducting wire of wired controller is short circuited IDU mainboard is abnormal Mainboard of wired controller is abnormal Troubleshooting 1 3 15 L5 Freeze protection Error display IDU wired...

Страница 151: ...r display IDU wired controller and IDU receive light board will display Error judgment condition and method No master IDU error will happen when there is no master IDU in the system Possible reason Ma...

Страница 152: ...roup controlled IDU quantity Possible reason IDU quantity connected with one wired controller exceeds 16 sets Actually connected IDU quantity is inconsistent with the set group controlled IDU quantity...

Страница 153: ...e the ODU with suitable model 2 After sales Emergency Masures When some unrecoverable fault occurs to one module which is connected with several others in parallel the following emergency measures are...

Страница 154: ...door Unit 148 3 Wiring Diagram NOTICE This drawing is just for reference please always refer to the electric wiring stuck to the unit for actual wiring 3 1 Low Static Pressure Duct Type Indoor Unit Mo...

Страница 155: ...REE Multi Variable Air Conditioners Indoor Unit 149 3 2 Slim Duct Type Indoor Unit Model GMV ND06PLS B T U GMV ND24PLS B T U 3 3 Four way Cassette Type Indoor Unit Model GMV ND07T A T U GMV ND48T A T...

Страница 156: ...REE Multi Variable Air Conditioners Indoor Unit 150 3 4 Wall Mounted Type Indoor Unit Model GMV N07G A3A D U GMV N24G A3A D U GMV N07G E3A D U GMV N24G E3A D U Model GMV ND06G B4B T U GMV ND24G B4B T...

Страница 157: ...GREE Multi Variable Air Conditioners Indoor Unit 151 Model GMV ND30G B4B T U GMV ND36G B4B T U 3 5 Console Type Indoor Unit Model GMV ND07C A T U GMV ND18C A T U...

Страница 158: ...GREE Multi Variable Air Conditioners Indoor Unit 152 3 6 High Static Pressure Duct Type Indoor Unit Model GMV ND18PHS A T U GMV ND48PHS A T U Model GMV ND72PH A T U GMV ND96PH A T U...

Страница 159: ...E Multi Variable Air Conditioners Indoor Unit 153 3 7 Two way Cassette Type Indoor Unit Model GMV ND09TS A T U GMV ND24TS A T U 3 8 Floor Ceiling Type Indoor Unit Model GMV ND09ZD A T U GMV ND48ZD A T...

Страница 160: ...GREE Multi Variable Air Conditioners Indoor Unit 154 3 9 Fresh Air Processing Indoor Unit Model GMV NDX42P A T U GMV NDX48P A T U Model GMV NDX54P A T U GMV NDX72P A T U GMV NDX96P A T U...

Страница 161: ...le Air Conditioners Indoor Unit 155 3 10 Compact Four way Cassette Type Indoor Unit Model GMV ND07T B T U GMV ND18T B T U 3 11 Super High Static Pressure Duct Type Indoor Unit Model GMV ND07PHS B T U...

Страница 162: ...GREE Multi Variable Air Conditioners Indoor Unit 156 Model GMV ND30PHS B T U GMV ND42PHS B T U Model GMV ND48PHS B T U GMV ND54PHS B T U...

Страница 163: ...ndoor Unit 157 Model GMV ND72PH B T U GMV ND96PH B T U 3 12 Air Handler type Indoor Unit Model GMV ND09A A T U GMV ND12A A T U GMV ND18A A T U GMV ND24A A T U GMV ND30A A T U GMV ND36A A T U GMV ND42A...

Страница 164: ...ir Conditioners Indoor Unit 158 3 13 AHU KIT Model GMV N12U A T U GMV N24U A T U GMV N48U A T U GMV N96U A T U GMV N192U A T U 3 14 1 way Cassette Type Indoor Unit Model GMV ND07TD A T U GMV ND09TD A...

Страница 165: ...9 3 15 Low Static Pressure Duct Type Indoor Unit Model GMV ND30PLS C T U GMV ND48PLS C T U 3 16 360 Air Discharge Compact Casssette Type Indoor Unit Model GMV ND05T E T U GMV ND07T E T U GMV ND09T E T...

Страница 166: ...filter from the air return frame 3 Remove the air return cover plate Use a screwdriver to unscrew the air return cover plate 4 Remove the rear volute casing Loosen the fasteners that connect the rear...

Страница 167: ...driver to unscrew the cover plate of the electric box and then remove the line connecting to the motor 3 Remove the rear volute casing Loosen the fasteners that connect the rear volute casing with the...

Страница 168: ...ray 2 Remove the water tray Water tray Remove the water tray 3 Unscrew the centrifugal fan Use a wrench to unscrew the centrifugal fan 4 Remove the centrifugal fan Centrifugal fan Remove the centrifug...

Страница 169: ...cedure 1 Unscrew the water tray Loosen the screws Use a screwdriver to unscrew the water tray 2 Remove the water tray Water tray Replace the water tray 3 Remove the drainage duct and unscrew the pump...

Страница 170: ...xle bush of the louver Remove the louver 2 Open the front panel Hold the indents on both sides of the panel and pull it out in the direction shown by the arrow 3 Remove the electrical box cover 2 Unsc...

Страница 171: ...evaporator Use a screwdriver to unscrew the screws fixing the press plate of connection pipe on the back of the unit and take off the press plate Unscrew the screws of evaporator with a screwdriver an...

Страница 172: ...asps at both sides to OPEN position 2 Remove filter and front case Remove 5 screws fixing the front case 3 Remove electric box Open electric box cover loosen all connection wires and then remove screw...

Страница 173: ...GMV ND18PHS A T U units For other units the assembly and disassembly procedure is similar except the specifications of centrifugal fans and motors Motor and fan Precondition The power supply has been...

Страница 174: ...or and centrifugal fan Use a screwdriver to unscrew the centrifugal fan Loosen the fasteners of the motor and remove the motor from the support For motors that are accompanied with supports the suppor...

Страница 175: ...the line connecting to the motor Use a screwdriver to unscrew the electric box cover Remove from the master board the line connecting to the motor and remove the tie 3 Remove the motor Rem ove the mo...

Страница 176: ...left and right cover plates Use a screwdriver to unscrew the left and right cover plates and then remove the cover plates 3 Remove the electric box cover and the line connecting to the motor Use a scr...

Страница 177: ...sed on the reverse order of this procedure and power on the units for test 4 9 Fresh Air Processing Indoor Unit GMV NDX42P A T U GMV NDX48P A T U Motor and fan Precondition The power supply has been d...

Страница 178: ...NDX72P A T U GMV NDX96P A T U Motor and fan Precondition The power supply has been disconnected Step Diagram Operation Procedure 1 Remove the cover plate component Use a screwdriver to unscrew the co...

Страница 179: ...everse order of this procedure and power on the units for test 4 10 Compact Four way Cassette Type Indoor Unit Motor and fan Step Diagram Operation Procedure 1 Unscrew the water tray Use a screwdriver...

Страница 180: ...r to unscrew the motor 6 Replace the motor with a new one Replace the motor with a new one 7 Screw the motor Use a screwdriver to screw the motor 8 Install and screw the centrifugal fan Install the ce...

Страница 181: ...screw the water tray 2 Remove the water tray Replace the water tray 3 Remove the drainage duct and unscrew the pump Remove the drainage duct and use a screwdriver to unscrew the pump 4 Replace the pum...

Страница 182: ...nd motors Motor and fan Precondition The power supply has been disconnected Step Diagram Operation Procedure 1 Remove the line connecting to the motor Use a screwdriver to unscrew the electric box cov...

Страница 183: ...r on the units for test GMV ND72PH B T U GMV ND96PH B T U Motor and fan Precondition The power supply has been disconnected Step Diagram Operation Procedure 1 Remove the line connecting to the motor U...

Страница 184: ...s procedure and power on the units for test 4 12 Air Handler type Indoor Unit Motor and fan Precondition The power supply has been disconnected Procedures Diagrams Operating Instructions 1 Remove the...

Страница 185: ...the motor bracket After the installation reassemble the unit as before 4 13 1 way Cassette Type Indoor Unit Motor and fan Step Diagram Operation Procedure 1 Unscrew the water tray Use a screwdriver to...

Страница 186: ...essing board Use a screwdriver to unscrew the motor pressing board 8 Remove the pressing board and replace the motor Remove the pressing board and replace the motor 9 Screw the motor pressing board Us...

Страница 187: ...NOTICE The following steps are specific for GMV ND30PLS C T U GMV ND48PLS C T U units the assembly and disassembly procedure is similar except the numbers of centrifugal fans and motors Motor and fan...

Страница 188: ...gon to unscrew the centrifugal fan and loosen the fasteners of the motor 7 Remove the motor Remove the motor from the support and remove the centrifugal fan from the motor axle Then remove the motor F...

Страница 189: ...Remove the cover of electric box and the clamp of power cord Remove the motor wire and water pump of the electric box 4 Remove the water tray Loosen the screws in the 4 corners and then remove the wa...

Страница 190: ...en the 4 screws of motor with a screwdriver 8 Install the fan Direct the hole of fan to the motor shaft and then mount on the fan Tighten the clamping band of motor with a wrench 9 Install the water t...

Страница 191: ...Assy 01265325 1 01265325 1 2 Evaporator Assy 01024100155 1 01024100136 1 3 Water Tray Assy 01285332 1 01285332 1 4 Right Side Plate Assy 01315335 1 01315335 1 5 Supporter 01895225 2 01895225 2 6 Centr...

Страница 192: ...Pump 43130324 1 43130324 1 22 Water Level Switch 45020216 1 45020216 1 23 Cover of air outlet 01265298 1 01265298 1 24 Air Outlet Frame Assy 01374636 1 01374636 1 25 Filter Sub Assy 26 Strainer 074141...

Страница 193: ...Board 4201800002601 1 16 Electric Box Cover 01424100035 1 17 Sealplate sub assy drainage 01495315 1 18 Sealplate sub assy outlet 01495316 1 19 Left Side Plate Assy 01315200087 1 20 Main Board 30226000...

Страница 194: ...5339 1 2 Water Tray Assy 01285334 1 3 Supporter 01895225 2 4 Right Side Plate Assy 01305263 1 5 Centrifugal fan assy 15404100024 1 6 Support Of Motor Bearing 01792408 1 7 O Gasket of Bearing 76512404...

Страница 195: ...Box Cover 01424100035 1 24 Left Side Plate Assy 01315200087 1 25 Choke Plug of Drain Pipe 76815214 2 26 Cover of Air Outlet 01265335 1 27 Air Outlet Frame Assy 01374635 1 28 Water Pump 43130324 1 29 W...

Страница 196: ...CM810N1720 GMV ND09PLS B T U CM810N1710 Part code Quantity Part code Quantity 1 Air Outlet Frame Assy 000141000012 1 000141000012 1 2 Evaporator Assy 011001000363 1 011001000360 1 3 Electric Expand Va...

Страница 197: ...01110602 1 17 Hook 2 01344100034 2 01344100034 2 18 Left Side Plate Assy 000080060035 1 000080060035 1 19 Filter Sub Assy 111001000082 2 111001000082 1 20 Propeller Housing Upper 26905200018 2 2690520...

Страница 198: ...ame Assy 000141000011 1 2 Evaporator Assy 01100100036201 1 3 Electric Expand Valve Fitting 4304413215 1 4 Strainer 0721200102 1 5 Electronic Expansion Valve 07334466 1 6 Liquid Level Switch 4300240000...

Страница 199: ...9 Top Cover Board Assy 000132060036 1 30 Cover Of Air In 01265200073 1 31 Hook 02112446 2 32 Display Board 30296000040 1 33 Sensor Sub assy 390002000005 1 34 Right Side Plate Assy 01314100115 1 35 Dra...

Страница 200: ...3 Propeller Housing Lower 26905200019 3 24 Joint Slack 73018731 1 25 Propeller Housing Upper 26905200018 3 26 Corrugated Pipe 05015408 1 27 Brushless DC Motor 15010406000901 1 28 Blower Mounting Plate...

Страница 201: ...it Product Code GMV ND24PLS B T U CM810N1670 Part code Quantity 1 Air Outlet Frame Assy 000141000013 1 2 Evaporator Assy 011001000402 1 3 Electric Expand Valve Fitting 4304413215 1 4 Strainer 07212001...

Страница 202: ...ring 76512210 1 22 Rotary Axis Sub Assy 73018761 2 23 Centrifugal Fan 10425200003 4 24 Propeller Housing Lower 26905200019 4 25 Joint Slack 73018731 2 26 Propeller Housing Upper 26905200018 4 27 Brush...

Страница 203: ...Quantity 1 Electric Box cover 0142410004801 1 2 Electric Box Assy 01394100434 1 3 Terminal Board 42011222 1 4 Terminal Board 4201800002601 1 5 Main Board 30226000029 1 6 Electric base plate 01412721 1...

Страница 204: ...1 17 Pump Drainpipe 05232721 1 18 Right Side Plate 01302734 1 19 Base Plate Assy 01222701 1 20 Brushless DC Motor 15704100007 1 21 Rear Side Plate 01302732 1 22 Remote Controller 30510589 1 23 Drain...

Страница 205: ...g unit Unit Product Code Unit Product Code GMV ND09T A T U CM500N0530 GMV ND15T A T U CM500N0670 GMV ND12T A T U CM500N0540 GMV ND18T A T U CM500N0510 GMV ND24T A T U CM500N0550 Part code Quantity Par...

Страница 206: ...1 01302707 1 18 Base Plate Assy 01222701 1 01222701 1 19 Brushless DC Motor 15709400004 1 15709400004 1 20 Rear Side Plate 01302703 1 01302703 1 21 Remote Controller 30510589 1 30510589 1 22 Drain Hos...

Страница 207: ...late 01302725 1 13 Front Side Plate 01302721 1 14 Water Level Switch 45020216 1 15 Water Pump 43138000068 1 16 Pump Drainpipe 05230026 1 17 Right Side Plate 01302727 1 18 Base Plate Assy 01222701 1 19...

Страница 208: ...03 2 2 Guide groove of the filter screen 02285301 1 3 Evaporator Assy 01024100090 1 4 Electric Expand Valve Fitting 4304413215 1 5 Electronic Expansion Valve 07334466 1 6 Strainer 0741410000601 1 7 Fi...

Страница 209: ...ance 43128000014 1 21 Electric Box Cover 01424100132 1 22 Centrifugal fan assy 15405200029 1 23 Blower Mounting Plate Sub Assy 01325200039 1 24 Supporter 01804100140 1 25 Blower 15012454 1 26 Brushles...

Страница 210: ...0180 GMV ND48PHS A T U CM810N0190 Part code Quantity 1 Filter Sub Assy 111253031 2 2 Side Plate of Air intake 01375301 1 3 Evaporator Assy 01024100077 1 4 Strainer 0741410000601 2 5 Strainer 07220005...

Страница 211: ...Board 4201800002601 1 18 Terminal Board 4201115402 1 19 Inductance 43128000014 1 20 Electric Box Cover 01424100132 1 21 Blower Mounting Plate Sub Assy 01325200044 1 22 Propeller Housing Upper 26904100...

Страница 212: ...y 01264100086 1 01264100090 1 2 Evaporator Assy 01024100119 1 01024100124 1 3 Display Board 30296000040 1 30296000040 1 4 Hook 02112466 4 02112466 4 5 Water Tray Assy 01284620 1 01284305 1 6 Bottom Co...

Страница 213: ...4 1 18 Radiator 49018000068 1 49018000068 1 19 Choke Plug of Water Pipe 76712454 2 76712454 2 20 Sensor Sub assy 39008000103G 1 39008000103G 1 21 Filter Sub Assy 11725211 2 11724102 2 22 Strainer 0741...

Страница 214: ...Expansion Valve 07334494 1 07334494 1 15 Strainer 0741410000601 2 0741410000601 2 16 Evaporator Assy 0102410009401 1 01024100094 1 17 Water Tray Sub Assy 01284100137P 1 01284100137P 1 18 Propeller Ho...

Страница 215: ...xpansion Valve 07334494 1 07334494 1 15 Strainer 0741410000601 2 0741410000601 2 16 Evaporator Assy 0102410009402 1 01024100093 1 17 Water Tray Sub Assy 01284100137P 1 01284100137P 1 18 Propeller Hous...

Страница 216: ...41601 1 17 Fixed Mount 26909426R 1 26909426R 1 18 Display Board 30294000009 1 30294000009 1 19 Rear Side Plate Assy 01319400008 1 01319400008 1 20 Evaporator Assy 01024100126 1 01024100096 1 21 Rotati...

Страница 217: ...it Product Code GMV ND18ZD A T U CM600N0440 Part code Quantity 1 Sensor Sub assy 39008000101G 1 2 Connection Board 02229406 1 3 Right Cover Plate 26909444 1 4 Plate Board of Water Releasing Flume 2690...

Страница 218: ...04 1 34 Support Of Motor Bearing 01792408 2 35 O Gasket of Bearing 76512404 2 36 Rotary Axis Sub Assy 73018000037 2 37 Centrifugal Fan 10425200 4 38 Joint Slack 73018731 2 39 Supporter 01809400002 1 4...

Страница 219: ...T U CM600N0460 Part code Quantity 1 Remote Controller 30510589 1 2 Sensor Sub assy 39008000100G 1 3 Water Tray Assy 01289405 1 4 Swing Lever 10582008 2 5 Air Louver 26909418 18 6 Swing Lever 10582009...

Страница 220: ...26909430 6 24 Fixed Mount 26909426R 1 25 Display Board 30294000009 1 26 Front Connection Board Foam Assy 12509424 1 27 Rear Side Plate Assy 01319400005 1 28 Water Releasing Flume 02289402P 1 29 Rotat...

Страница 221: ...otary Axis Sub Assy 73018052 1 50 Joint Slack 73018731 1 51 Motor Support Sub Assy 01809400029 1 52 Brushless DC Motor 15705200005 1 53 Rear volute casing 26909419 3 54 Filter 11126002 1 55 Top Cover...

Страница 222: ...leasing Flume 26909442 1 12 Water Releasing Flume 26909441 1 13 connected board evaporator 01344108 1 14 Strainer 0741410000601 2 15 Electronic Expansion Valve 07334468 1 16 Electric expand valve fitt...

Страница 223: ...6512404 2 39 Bracket 1 01809404 1 40 Clapboard Sub Assy 01249400006 1 41 Front volute casing 26905208 4 42 Rear volute casing 26909419 4 43 Rear Connection board 01349419 1 44 Rotary Axis Sub Assy 730...

Страница 224: ...12210 1 76512210 1 5 Propeller Housing Lower 26905200079 3 26905200079 3 6 Brushless DC Motor 1570940000601 1 1570940000601 1 7 Centrifugal Fan 10455200003 3 10455200003 3 8 Joint Slack 73018731 1 730...

Страница 225: ...ic Expansion Valve 07334468 1 07334468 1 26 Strainer 7415210 1 7415210 1 27 Foam Sub Assy Water Tray 12505200021 1 12505200021 1 28 Top Cover Board Assy 01264100105 1 01264100105 1 29 Right Side Plate...

Страница 226: ...0 1 01284620 1 13 Bottom Cover Plate Assy 01264100087 1 01264100087 1 01264100087 1 14 Choke Plug of Water Pipe 76712454 2 76712454 2 76712454 2 15 Electric Box Assy 01394100619 1 01394100619 1 013941...

Страница 227: ...C A T U CM400N0120 GMV ND12C A T U CM400N0100 GMV ND18C A T U CM400N0130 Part code Quantity 1 Front Panel Assy 20012756 1 2 Filter Sub Assy 11122139 1 3 Front Case Assy 20012601 1 4 Air Louver lower 1...

Страница 228: ...0052011 1 21 Rear Case 22202461 1 22 Top Side Plate 20052013 1 23 Right Side Plate 20052012 1 24 Diversion Circle 10371212 1 25 Louver Motor Sub assy 00021100001 1 26 Swing Lever 10582096 2 27 Guide L...

Страница 229: ...B1 20012122S 1 4 Filter Sub Assy 1112220403 1 5 Front Case Sub assy 2001213931 1 6 Evaporator Assy 01024100102 1 7 Strainer 07414100006 4 8 Strainer 07213050 4 9 Electronic Expansion Valve 07334463 4...

Страница 230: ...16702 1 25 Connecting pipe clamp 26112164 1 26 Stepping Motor 1521212901 1 27 Crank 10582070 1 28 Wall Mounting Frame 01252021 1 29 Rear Case Sub Assy 2220294712 1 30 Air Louver 1 10512164 1 31 Air Lo...

Страница 231: ...Cover of Electric Box 01592092 1 16 Electric Box Cover1 2012215401 1 17 Display Board 30565038 1 18 Remote Controller 30510589 1 19 Lower Shield of Electric Box 01592091 1 20 Electric Box Assy 013941...

Страница 232: ...1112220403 1 5 Front Case Sub assy 2001213931 1 6 Evaporator Assy 01024100097 2 7 Strainer 07414100006 4 8 Strainer 07213050 4 9 Electronic Expansion Valve 07334463 4 10 Electric Expand Valve Fitting...

Страница 233: ...nnecting pipe clamp 26112164 1 26 Stepping Motor 1521212901 2 27 Crank 10582070 2 28 Wall Mounting Frame 01252021 1 29 Rear Case Sub Assy 2220294712 2 30 Air Louver 1 10512164 2 31 Air Louver 2 105121...

Страница 234: ...ame of part For the following unit Unit Product Code GMV ND06G B4B T U CM100N2950 GMV ND07G B4B T U CM100N2960 GMV ND09G B4B T U CM100N2970 GMV ND12G B4B T U CM100N2980 Part code Quantity 1 Front Pane...

Страница 235: ...002201 1 21 Sealing Cap PressureWarning 2611219201 1 22 Evaporator Assy 011001060163 1 23 Drainage Hose 05230014 1 24 O Gasket of Cross Fan Bearing 76512203 1 25 Fan Bearing 7651221001 1 26 Ring of Be...

Страница 236: ...05230014 1 24 O Gasket of Cross Fan Bearing 76512203 1 25 Fan Bearing 7651221001 1 26 Ring of Bearing 26152025 1 27 Left Axile Bush 10512037 1 28 Temperature Sensor 390000454 1 29 Temperature Sensor...

Страница 237: ...18 Filter Sub Assy 30209060001 1 19 Electronic Expansion Valve 7334466 1 20 Strainer A 721002201 1 21 Sealing Cap PressureWarning 2611219202 1 22 Evaporator Assy 11001060225 1 23 Drainage Hose 0523001...

Страница 238: ...GREE Multi Variable Air Conditioners Indoor Unit 232 GMV ND30G B4B T U GMV ND36G B4B T U...

Страница 239: ...40 1 16 Screw Cover 242520053 4 17 Rubber Plug Water Tray 76712012 1 18 Rear Case Sub Assy 22202703 1 19 Cross Flow Fan 1 10352039 1 20 Bearing Holder Sub assy 26152028 1 21 Cross Flow Fan 2 10352040...

Страница 240: ...90000454 1 Above data is subject to change without notice please reference the SP in global service website 5 10 Compact Four way Cassette Type Indoor Unit Exploded View of GMV ND07T B T U GMV ND09T B...

Страница 241: ...0002601 1 15 Electric Box Assy 100002001831 1 100002001831 1 16 Electric Box Cover 01429400002 1 01429400002 1 17 Left Side Plate Sub Assy 01319400012 1 01319400012 1 18 Centrifugal Fan 10429400001 1...

Страница 242: ...ver 01429400002 1 17 Left Side Plate Sub Assy 01319400012 1 18 Centrifugal Fan 10429400001 1 19 Remote Controller 30510589 1 20 Drain Hose Sub Assy 05232050 1 21 Strainer 0741410000601 2 22 Electronic...

Страница 243: ...79 1 26905200079 1 15 Filter Sub Assy 111001000055 1 111001000055 1 16 Foam Sub assy 12505200038 1 12505200038 1 17 Cover Of Air In 01265200182 1 01265200182 1 18 Bottom Cover Plate 01265200181 1 0126...

Страница 244: ...S B T U GMV ND24PHS B T U Qty Product Code CM810N0800 CM810N0770 CM810N0810 CM810N0720 CM810 N0730 Part Name Part Code 1 Centrifugal Fan Assy 017026000002 1 2 Filter Sub Assy 111001000045 2 3 Propelle...

Страница 245: ...rd 30226000089 1 19 Terminal Board 4201800002601 1 20 Air Outlet Frame Assy 01375200026 1 21 Evaporator Assy 01024100173 0102410017301 1 22 Sealing Cap Pressure Warning 2611219201 1 23 Electric Expand...

Страница 246: ...roduct Code CM810N0780 CM810N0740 CM810N0750 Part Name Part Code 1 Filter Sub Assy 111001000052 3 2 Return Air Frame Sub Assy 017026000003 1 3 Propeller Housing Upper 26905200078 3 4 Fan Bearing 76512...

Страница 247: ...1 22 Electric Box Assy 100002000984 1 23 Air Outlet Frame Assy 01375200023 1 24 Evaporator Assy 011001000070 1 25 Electric Expand Valve Fitting 4304413215 1 26 Strainer 0741410000601 1 27 Electronic E...

Страница 248: ...Assy 111001000052 3 2 Return Air Frame Sub Assy 017026000003 1 3 Centrifugal Fan Assy 000052000029 1 4 Propeller Housing Upper 26905200078 3 5 Propeller Housing Lower 26905200079 3 6 Centrifugal Fan...

Страница 249: ...Sensor 3900005910 1 26 Temperature Sensor 390000592 1 27 Temperature Sensor 390000454 1 28 Air Outlet Frame Assy 01375200023 1 29 Strainer 0741410000601 1 30 Electric Expand Valve Fitting 4304413215 1...

Страница 250: ...t Name Part Code 1 Front Side Plate Sub Assy 017101060001 1 2 Motor for Centrifugal Fan 103004000106 1 3 Brushless DC Motor 15704100009 1 4 Motor for Centrifugal Fan 103004000105 1 5 Bottom Cover Plat...

Страница 251: ...for Centrifugal Fan 103004000106 1 3 Brushless DC Motor 15704100009 1 4 Motor for Centrifugal Fan 103004000105 1 5 Bottom Cover Plate 012147060003 2 6 Bottom Cover Plate 012147060002 1 7 Water Tray As...

Страница 252: ...GMV ND12A A T U Qty Product Code CM810N1900 CM810N1910 Part Name Part Code 1 insulating board 75142201 1 2 Lower cover plate 1 01264100070 1 3 Top Cover Board Sub assy 01262200007 1 4 Plastic Cover 26...

Страница 253: ...7 Top Cover Plate Sub Assy 01262200010 1 28 Left Side Plate Sub Assy 01312200005 1 29 Sensor Sub Assy 39008000103G 1 30 Display Board 30296000040 1 Exploded View of GMV ND18A A T U GMV ND24A A T U GMV...

Страница 254: ...ay Board 30296000040 1 Exploded View of GMV ND36A A T U GMV ND42A A T U NO Model GMV ND36A A T U GMV ND42A A T U Qty Product Code CM810N0700 CM810N0690 Part Name Part Code 1 insulating board 75142201...

Страница 255: ...1 01264100065 1 3 Top Cover Board Sub assy 01262200024 1 4 Plastic Cover 26902209 4 5 Lower cover plate sub assy 2 01262200026 1 6 Evaporator Assy 01024100159 1 7 Current Divider 0722443501 1 8 Strain...

Страница 256: ...0040 1 Above data is subject to change without notice please refer the SP in global service website 5 13 AHU KIT Exploded View of GMV N12U A T U NO Model GMV N12U A T U Qty Product Code CN750N0101 Par...

Страница 257: ...d 4201025901 1 6 Terminal Board 42011154 1 7 Terminal Board 4201800002601 1 8 Terminal Board 42011147 1 9 Electronic Expansion Valve assy 030174000027 1 10 Strainer 0741410000601 2 11 Electronic Expan...

Страница 258: ...ic Box Assy 100002002825 1 2 Main Board 30226000081 1 3 Transformer 43110286 1 4 Terminal Board 4201115402 1 5 Terminal Board 4201025901 1 6 Terminal Board 42011154 1 7 Terminal Board 4201800002601 1...

Страница 259: ...9 2 4 Electronic Expansion Valve 07331139 2 5 Bidirection Strainer 0721004401 2 6 Electric Box Assy 100002002825 1 7 Main Board 30226000081 1 8 Transformer 43110286 1 9 Terminal Board 4201115402 1 10...

Страница 260: ...U CM502N0151 GMV ND09TD A T U CM502N0161 Part code Quantity Part code Quantity 1 Remote Controller 30510589 1 30510589 1 2 Drain Hose Sub Assy 05232050 1 05232050 1 3 Temperature Sensor 39008000079G 1...

Страница 261: ...1 02224100007 1 23 O Gasket of Cross Fan Bearing 76512203 1 76512203 1 24 Chassis Assy 01194100007 1 01194100007 1 25 Left Side Plate Sub Assy 01314100022 1 01314100022 1 Above data is subject to chan...

Страница 262: ...e sub assy 02224100007 1 23 O Gasket of Cross Fan Bearing 76512203 1 24 Chassis Assy 01194100007 1 25 Left Side Plate Sub Assy 01314100022 1 Above data is subject to change without notice please refer...

Страница 263: ...Board 300020060016 1 300020060016 1 14 Terminal Board 4201110602 1 4201110602 1 15 Terminal Board 42200006000401 1 42200006000401 1 16 Main Board 300002060459 1 300002060459 1 17 Main Board 300002060...

Страница 264: ...ariable Air Conditioners Indoor Unit 258 5 16 360 Air Discharge Compact Casssette Type Indoor Unit Exploded View of GMV ND05T E T U GMV ND07T E T U GMV ND09T E T U GMV ND12T E T U GMV ND15T E T U GMV...

Страница 265: ...32 1 6 Strainer 07216221 1 7 Electronic Expansion Valve 072009000006 1 8 Electric Expand Valve Fitting 43040001 1 9 Shell Assy 011633060005 1 10 Mounting Rack Sub Assy 017044060011 4 11 Remote Control...

Страница 266: ...JF00302921...

Отзывы: