GREE
Multi Variable Air Conditioners Indoor Unit
165
Removal of Fan Motor
Remark: before removing, making sure power is disconnected.
Step
Diagram
Operation Procedure
(6) Remove
the main
board.
Release the wiring terminals
connected to the main board.
Remove the main board.
(7) Remove
the
electrical
box.
Unscrew the screws fixing the
electrical box with a
screwdriver.
Remove the electrical box.
(8) Remove
the
evaporator.
Use a screwdriver to unscrew
the screws fixing the press plate
of connection pipe on the back
of the unit and take off the press
plate.
Unscrew the screws of
evaporator with a screwdriver
and then remove the
evaporator.
(9) Remove
motor’s
pressing
plate.
Unscrew the fixing screws of the
pressing plate with a
screwdriver and then remove it.
(10) Remove
the motor
and fan.
Take off the motor and fan
directly.
Use a screwdriver to unscrew
the screws connecting the
motor and the fan.
(11) Install a
new motor.
Assemble units based on the
reverse order of this procedure
and power on the units for test.
Содержание CM100N1480
Страница 7: ...GREE Multi Variable Air Conditioners Indoor Unit 1 PRODUCT...
Страница 51: ...GREE Multi Variable Air Conditioners Indoor Unit 45 CONTROL...
Страница 52: ...GREE Multi Variable Air Conditioners Indoor Unit 46 CHAPTER 2 CONTROL 1 Operation Flowchart...
Страница 95: ...GREE Multi Variable Air Conditioners Indoor Unit 89 INSTALLATION...
Страница 139: ...GREE Multi Variable Air Conditioners Indoor Unit 133 MAINTENANCE...
Страница 238: ...GREE Multi Variable Air Conditioners Indoor Unit 232 GMV ND30G B4B T U GMV ND36G B4B T U...
Страница 266: ...JF00302921...