Select ADM Settings
Note
See
for
detailed ADM information, including general
operation.
1. Turn main power switch on.
2. When the ADM is finished starting up, press
to switch from the Operation screens to
the Setup screens. Use the arrows to navigate
between screens.
3. Check system settings on the System 1 screen.
4. Set alarm levels on the System 2 screen.
5. Set primary system setpoint and setback
temperatures for the pump, platen, and heat
zones on the Heat-A screens.
Note
Setback temperatures must be at least
20°F (10°C) lower than the setpoint
temperatures
Note
To ensure accurate hose temperatures,
be sure all heated hoses have their
“zone type” set to “Hose.” Hoses are only
present on odd zone numbers: 1, 3, 5,
7, 9, or 11.
a. Select the appropriate “Zone Type” for all
installed zones.
b. Check the “A” and “B” boxes according to
which systems needs to use the heated
accessory.
6. If a secondary system is used, set temperatures
on the Heat-B screens.
7. Set the system date and time on the Advanced 1
screen.