10. Remove the air motor top cover.
11. Disconnect electrical cable from air motor.
12. Remove air line from air motor and air lines to the
follower blow-off valve.
13. Tightly strap the air motor to the tie bar with a
cable through the air motor lift ring and around
the tie bar. See
14. Loosen u-bolts (X) from platen lift rods.
15. Remove nuts (F) from pump/air motor stand-off
rods at the pump end.
16. Remove nuts (Z) and bolts holding cable tract to
air motor support plate.
17. Slide end of cable track outboard of the mounting
plate.
18. Remove nuts (N) from follower lift rods.
19. Fully loosen pump rod coupler to the air motor
rod (G).
20. Slowly raise elevator to achieve enough
separation of the pump (air motor) tie rods to
remove the pump.
21. Remove the pump.
22. Reverse this procedure to reinstall the new or
rebuilt air motor.
48
334130A
Содержание 334130A
Страница 10: ...Component Identification Electrical Control Enclosure Figure 3 Electrical Enclosure 10 334130A...
Страница 57: ...Repair Figure 35 Inside of Electrical Control Enclosure 334130A 57...
Страница 65: ...Parts Parts Therm O Flow 200 Supply Unit 334130A 65...
Страница 68: ...Parts Electrical Module 68 334130A...
Страница 69: ...Parts 334130A 69...