Heat-A
Use these screens to set target and setback
temperatures for the pump, platen, and zones. Select
which system needs to use the heated accessory.
Zone Types:
• Hose
• Gun
• PGM
• Flowmeter
• Pressure Regulator
• Manifold
• Other
Note
To ensure accurate hose and gun
temperatures, set hose as zone 1, 3, 5, 7, 9,
or 11 when cable 17C694 is connected to
MZLP and a heated hose.
Maintenance-A
The system will notify the user at the set interval that
maintenance is required. The fields in boxes can
be edited by the user. “Due” and “Current” are both
the number of cycles since the last reset. “Interval”
is the set number of cycles between maintenance
notifications. “Lifetime” is the number of cycles in the
lifetime of the system.
Note
The lifetime cycle count will only be reset if
the ADM is replaced.
Schedule
Use this screen to set times that the system
will automatically enable and disable heating.
See
.
102
334130A