Load Material
NOTICE
To prevent damage to platen wipers, do not use a
drum of material that has been dented or damaged.
An empty drum clamp can interfere with up and
down operation of the ram. When raising the
ram, make sure the drum clamp stays clear of the
platen.
Note
Before loading material, make sure there is a
minimum overhead clearance of 110 in. (280
cm) and all air regulators are backed off to
their full counterclockwise position.
1. Open the main air slider valve (CA).
2. Set ram director valve (CC) to UP and slowly
turn the ram up regulator (CD) clockwise until the
platen (G) begins to rise.
Figure 18 Raise the Platen
3. Apply a thin coating of high temperature grease
lubricant (part no. 115982) to the platen drum
seals.
4. Fill displacement pump wet cup 2/3 full with
Graco Throat Seal Liquid (TSL™) for Butyl and
PSA materials.
Note
Use IsoGuard Select® (IGS) (part
no. 24D086) for PUR or reactive
Polyurethane material. IGS is
designed to dissolve and suspend the
Polyurethane materials. IGS will solidify
after a period of time and should be
replaced once the solidified lube does
not return to liquid form after heating.
Figure 19 Wetcup
5. Open drum, remove any packing material, and
inspect material for any contamination.
6. Slide the drum between the drum centering
guides and against the stops at the back of the
ram baseplate.
Figure 20 Drum Placement
334130A
31
Содержание 334130A
Страница 10: ...Component Identification Electrical Control Enclosure Figure 3 Electrical Enclosure 10 334130A...
Страница 57: ...Repair Figure 35 Inside of Electrical Control Enclosure 334130A 57...
Страница 65: ...Parts Parts Therm O Flow 200 Supply Unit 334130A 65...
Страница 68: ...Parts Electrical Module 68 334130A...
Страница 69: ...Parts 334130A 69...