Replace Heater Bands and Pump
RTD
Replace Heater Band
1. If the material drum has already been removed
from the supply unit, go to step 2. If you need
to remove the material drum, perform steps 1
through 6 of the
. Pump
must be in the full down position (air motor shaft
fully extended).
2. Make sure the ram plate is down and the ram
hand valve is in the neutral position.
3. Follow
Pressure Relief Procedure, page 36
.
4. Bleed off excess material and pressure in the
system by opening the applicator and catching
the material in a waste container.
5. On ADM, turn off the system heat (D).
6. Turn the main power switch off.
7. Remove the screws and covers.
8. Remove white ceramic caps and disconnect the
electrical wires from heater band (309).
9. Remove the screw that holds the heater band
in place.
10. Remove the heater band (309a, 309b) from
pump.
11. Coat the inside of the heater with non silicone
heat sink compound before mounting. Maximum
thickness is 0.005 in. Coat only to within 3/4 in.
of vertical ends.
12. Install a new heater band (309a, 309b) in the
same location as the old heater band:
a. Locate heater terminals so they line up with
back of pump.
b. Tighten the heater band.
c. Re-connect heater wires and re-attach
ceramic caps that insulate terminal.
Figure 30
50
334130A
Содержание 334130A
Страница 10: ...Component Identification Electrical Control Enclosure Figure 3 Electrical Enclosure 10 334130A...
Страница 57: ...Repair Figure 35 Inside of Electrical Control Enclosure 334130A 57...
Страница 65: ...Parts Parts Therm O Flow 200 Supply Unit 334130A 65...
Страница 68: ...Parts Electrical Module 68 334130A...
Страница 69: ...Parts 334130A 69...