Grounding
Ground the unit as instructed here and in the
component manuals.
The equipment must be grounded to reduce the
risk of static sparking and electric shock. Electric
or static sparking can cause fumes to ignite or
explode. Improper grounding can cause electric
shock. Grounding provides an escape path for the
electric current.
System: ground through ground lug in electrical
enclosure. See
Air and fluid hoses: use only electrically conductive
hoses.
Air compressor: follow manufacturer’s
recommendations.
Spray gun / Dispense valve: ground through
connection to a properly grounded fluid hose and
pump.
Material drums: follow local code. Use only metal
drums placed on a grounded surface. Do not place
the drum on a nonconductive surface, such as
paper or cardboard, which interrupts the grounding
continuity.
To maintain grounding continuity when flushing
or relieving pressure: follow instructions in your
separate gun manual for instructions on how to safely
ground your gun while flushing.
Connect Secondary System
A secondary system is a Therm-O-Flow supply
system that connects to the primary Therm-O-Flow
system, with the ADM. See
for
secondary system model numbers.
1. Connect adapter cable (AC) and communication
cable (SC) to the secondary electrical enclosure
and rout to splitter (SS) installed on the primary
system.
2. To enable a secondary system, select “Enable
Tandem System” on the System 1 screen. See
Figure 14
22
334130A
Содержание 334130A
Страница 10: ...Component Identification Electrical Control Enclosure Figure 3 Electrical Enclosure 10 334130A...
Страница 57: ...Repair Figure 35 Inside of Electrical Control Enclosure 334130A 57...
Страница 65: ...Parts Parts Therm O Flow 200 Supply Unit 334130A 65...
Страница 68: ...Parts Electrical Module 68 334130A...
Страница 69: ...Parts 334130A 69...