NXT 6500, 70:1 Pump Modules
1
Torque to 50–60 ft-lb (68–81 N•m).
2
Torque to 145–155 ft-lb (196–210 N•m).
3
Coat mounting surface of sensor mounting block
(411) with non-silicone heat sink compound. Do
not coat sensor.
4
Prior to tightening band clamp (412), RTDsensor
(410) must be fully contained within the sensor
mount (411).
5
After fastening band clamp (412), secure excess
with fiberglass tape.
6
Coat inside of heater (407) only to within 0.75 in.
(19 mm) of vertical ends) with non-silicone heat
sink compound before mounting.
8
Torque to 150 ft-lb (203 N•m).
10
Apply anaerobic sealant to threads.
334130A
79