Technical Specifications
Therm-O-Flow 200 Hot Melt System
U.S.
Metric
Displacement pump effective area
1.24 in.
2
8 cm
2
Volume per cycle
11.7 in.
3
192 cm
3
Pump cycles per 1 gallon (3.8
liters)
21
Ram maximum input pressure
125 psi
0.85 MPA, 8.5 bar
Maximum pump operating
temperature
400°F
204°C
Air inlet size
3/4 npsm(f)
Air motor sound data
See air motor instruction manual.
Pump fluid inlet size
1 in. npt(f)
Wetted Parts
carbon steel, brass, chrome, zinc, nickel plating, stainless steel (304,
316, 440, and 17–4 PH), alloy steel, ductile iron, PTFE
Maximum Fluid Working Pressure
Merkur 6.0 in.
2300 psi
15.9 MPa, 159 bar
Merkur 7.5 in.
3000 psi
20.7 MPa, 207 bar
NXT 6500
3000 psi
20.7 MPa, 207 bar
Maximum Air Input Pressure (Pumps)
Merkur 6.0 in.
100 psi
0.7 MPa, 7 bar
Merkur 7.5 in.
82 psi
0.57 MPa, 5.7 bar
NXT 6500
43 psi
0.29 MPa, 2.9 bar
Power Requirements
Compressed Air (typical)
25–50 scfm
Voltage (as selected)
220/240 V, 3-phase, 50/60 Hz
380/400 V, 3-phase, 50/60 Hz
470/490 V, 3-phase, 50/60 Hz
600 V, 3-phase, 50/60 Hz
Peak Consumption
(includes drum melt grid, pump, and a 6kVa transformer for the 230 V hoses and accessories)
with standard melt grid
27.1 kVa
with Mega-Flo melt grid
30.2 kVa
with smooth melt grid
27.1 kVa
334130A
107
Содержание 334130A
Страница 10: ...Component Identification Electrical Control Enclosure Figure 3 Electrical Enclosure 10 334130A...
Страница 57: ...Repair Figure 35 Inside of Electrical Control Enclosure 334130A 57...
Страница 65: ...Parts Parts Therm O Flow 200 Supply Unit 334130A 65...
Страница 68: ...Parts Electrical Module 68 334130A...
Страница 69: ...Parts 334130A 69...