Note
If a custom language file was installed, users
can now select the new language from the
Language drop-down menu.
Note
If the SETTINGS.TXT or DISPTEXT.TXT
files remain in the UPLOADfolder, they will
be uploaded every time the USB drive is
inserted into the corresponding ADM. To
avoid unintentionally overwriting system
settings, delete the files from the UPLOAD
folders on the USB drive after the upload is
complete.
USB Logs
During operation, the Therm-O-Flow stores system
and performance related information to memory in
the form of log files. The Therm-O-Flow maintains the
events, data, GCA, Black Box, and Diagnostics logs.
Follow the Download Procedure, to retrieve log files.
Events Log
The event log (1-EVENT.CSV) maintains a record of
the last 175,000 events. Each event record in the log
file contains the date and time the event occurred,
the event type, event code, and event description.
Data Log
The data log (2-DATA.CSV) tracks the setpoint and
actual temperatures every 15 seconds. This log can
store up to 250,000 lines of data.
The system stores 1041 hours of system operation
data, or 43 days of around-the-clock operation. Once
full, the system will overwrite the oldest data.
GCA Log
This log (3-GCA.CSV) lists the installed GCA
modules and their respective software versions.
Black Box, Diagnostics Log
These logs (4-BLACKB.CSV, 5-DIAGN.CSV) are
designed to provide useful information to Graco when
calling for technical assistance.
System Settings File
NOTICE
Uploading an edited system configuration file
can damage the system. Never put a modified
SETTNGS.TXT file in the UPLOAD folder on the
flash drive.
The system configuration settings file name is
SETTINGS.TXT and is stored in the DOWNLOAD
folder.
A system configuration settings file automatically
downloads each time a USB flash drive is inserted.
Use this file to back up system settings for future
recovery or to easily replicate settings across
multiple Therm-O-Flow systems. Refer to the
, for how to use this file.
It is recommended to retrieve the SETTINGS.TXT
file after all system settings are set as desired. Store
the file for future use as a backup in case the settings
are changed and need to be quickly changed back to
the desired setup.
Note
System settings may not be compatible
between different versions of the
Therm-O-Flow software.
104
334130A
Содержание 334130A