Troubleshooting
Light Tower (Optional)
Signal
Description
Red Light Off
If green light is also off, system power may be off or system operating mode is Inactive. If
green is on or flashing, there are no active errors.
Red Light On
User interaction required — alarm, system is shut down
Red Light
Flashing
User interaction required — advisory, deviation, or system is in a state that could prohibit
dispensing.
Green Light Off System is inactive
Green Light On System is ready to dispense. The heat and pump are on.
Green Light
Flashing
System will be ready to dispense in time without user interaction (heat on, pump off, and
temperature control zones have not reached set point)
Error Codes
There are three types of errors that can occur. Errors
are indicated on the display as well as by the optional
light tower.
Alarms are indicated by
. This condition indicates
a parameter critical to the process has reached a
level requiring the system to stop. The alarm needs
to be addressed immediately.
Deviations are indicated by
. This condition
indicates a parameter critical to the process has
reached a level requiring attention, but not sufficient
enough to stop the system at this time.
Advisories are indicated by
. This condition
indicates a parameter that is not immediately critical
to the process. The advisory needs attention to
prevent more serious issues in the future.
To acknowledge the error, press
.
The third digit, or sometimes the last digit of the error
code, indicates which unit the error is active on. The
“
★
” (star) character indicates the code applies to
multiple system components.
Third or Last Digit
Codes Relates To:
A
Unit A
B
Unit B
The last digit of the error code indicates which
zone, pump, or platen the error applies. The “_”
(underscore) character indicates the code applies to
multiple system components.
Last Digit
Codes Relates To:
1
Zone 1
2
Zone 2
3
Zone 3
4
Zone 4
5
Zone 5
6
Zone 6
7
Zone 7
8
Zone 8
9
Zone 9
A
Zone 10
B
Zone 11
C
Zone 12
DPump
E
Platen
V
AWB Unit A
W
AWB Unit B
X
Daughter Board Unit A
Y
Daughter Board Unit B
334130A
39
Содержание 334130A
Страница 10: ...Component Identification Electrical Control Enclosure Figure 3 Electrical Enclosure 10 334130A...
Страница 57: ...Repair Figure 35 Inside of Electrical Control Enclosure 334130A 57...
Страница 65: ...Parts Parts Therm O Flow 200 Supply Unit 334130A 65...
Страница 68: ...Parts Electrical Module 68 334130A...
Страница 69: ...Parts 334130A 69...