Screen Components
1. Screen Order
2. Current date and time
3. Operating Mode
4. Faults, Status
5. MZLP Plug Identifier
6. Zone Setpoint Temperature
7. Zone Actual Temperature
Operating Mode
Description
Component Status
System Off
The system does not have power.
• No system status indicator LEDon the
ADM
• No heat
• Pump is off
Inactive
The heating system and pumps are
disabled.
• Yellow system indicator LEDon the
ADM
• No heat
• Pump is off
Warm Up
The system is heating the material to the
setpoint temperature.
• Flashing green system status indicator
LEDon the ADM
• Heat is increasing to setpoint
temperature
• Pump is off
Heat Soak
Heat zones are all at temperature.
Material is soaking for a user specified
amount of time.
• Flashing green system status indicator
LEDon the ADM
• Heat is at setpoint
• Material is absorbing more heat
• Pump is off
• Heat soak counter counts down on the
Home screen.
Ready
All enabled zones are at setpoint
temperature. The air motor does not have
power.
• Flashing green system status indicator
LEDon the ADM
• Heat is at setpoint
• Pump is off
Active
The system is ready to dispense.
• Solid green system status indicator
LEDon the ADM
• Heat is at setpoint temperature
• Pump is on
14
334130A
Содержание 334130A
Страница 10: ...Component Identification Electrical Control Enclosure Figure 3 Electrical Enclosure 10 334130A...
Страница 57: ...Repair Figure 35 Inside of Electrical Control Enclosure 334130A 57...
Страница 65: ...Parts Parts Therm O Flow 200 Supply Unit 334130A 65...
Страница 68: ...Parts Electrical Module 68 334130A...
Страница 69: ...Parts 334130A 69...