5.3
Data Entry
Overview of Keyboard Entries via the Touchscreen Keyboard (feature E01)
5.3.1
Keyboard Entries via Touchscreen or External Keyboard
After selecting
ID
or any other object parameter, a keyboard is dis-
played which allows for the entry of alphanumeric characters via
the fixed function keys and the softkeys. Alternatively, entries can
also be made with the help of a USB keyboard or barcode scan-
ner which is connected to the instrument.
The keyboard layout can be matched to the language in SETUP.
Setup 1/3 > System 1/2 > Culture >
Keyboard Layout
(for alphanu-
meric entries)
Note
In order to use a USB keyboard at the SECUTEST..., the
“Keyboard Layout Settings” in Setup must coincide with
the connected keyboard.
See section 14.6 concerning switching to an external USB key-
board and special key functions.
Procedure (example: entering a designation):
1 Switch the keyboard back and forth between uppercase and
lowercase with the
button.
2 Select entry of numbers, special characters or letters via the
keyboard with the “123”, “sym” or “abc” button.
3 After pressing the respective icon it appears at the display
panel.
4 Repeat steps 1 through 3 until the complete designation is
shown at the display panel.
5 The value appears at the display after pressing the
green checkmark.
5.3.2
Data Entry via the Touchscreen Keyboard (feature E01)
The touchscreen keyboard permits convenient entry of data and
comments, selection of parameters and direct parameter selec-
tion, and menu-driven operation is still possible via the softkeys as
an alternative.
Meaning of Symbols in the User Interface – Database Management
Accept entry *
Display Panel
Keypad
Delete characters from right *
* Also via assigned softkey
➭
Briefly pressing the shift key
once causes the next char-
acter to appear in upper-
case.
➭
Pressing the shift key for a
longer period of time
causes all following charac-
ters to appear in upper-
case.
➭
The cursor can be posi-
tioned as desired by press-
ing the display panel at the
respective point in the exist-
ing text.
Symbol
Meaning
Main
Level
Sub-
level
Memory menu, page 1 of 3
Change display to menu selection
Cursor UP: scroll up
Cursor DOWN: scroll down
Cursor RIGHT: open tree
Cursor LEFT: close tree
Memory menu, page 2 of 3
Change display to menu selection
Add a structure element
Delete selected structure element or measurement
Edit structure element
(ID, designation, comment ...)
Move structure element
(feature KD01, “Z853S – SECUTEST DB COM-
FORT”)
When a measurement is selected: Display mea-
sured values
Display details from the measurement results list
Hide details from the measurement results list
Memory menu, page 3 of 3
Change display to menu selection
Search for ID, text or UDI > enter complete ID num-
ber (ID) or text (complete word)
Search for ID number: > Enter complete ID number
of a test object
Confirm search results
Display the structure designation
Hide the structure designation