102
GMC-I Messtechnik GmbH
12
Characteristic Values
Func-
tion
Measured
Quantity
Display Range/
Nominal Range
of Use
Reso-
lution
Nominal
Voltage
U
N
Open-
Circuit
Voltage
U
0
Nomi-
nal
Current
I
N
Short-
Circuit
Current
I
K
Internal
Resis-
tance
R
I
Refer-
ence
Resis-
tance
R
REF
Measuring
Uncertainty
Intrinsic
Uncertainty
Overload
Capacity
Value
Time
Te
sts
,
62638 (DI
N
VDE
0701-0702)
/
IEC
62
353
(VDE
0751)
Protective conduc-
tor resistance
R
PE
1
…
999 m
Ω
1 m
Ω
—
< 24 V
AC or DC
—
>
200 mA
AC / DC
> 10 A AC
5
>
35 A AC
11
—
—
±
(15% rdg.+ 10 d)
> 10 d
> 10.0
Ω
:
±
(10% rdg.+ 10 d)
±
(10% rdg.+ 10 d)
> 10 d
264 V
250 mA
16 A AC
5
Cont.
1.00 ... 9.99
Ω
10 m
Ω
10.0
…
27.0
Ω
100 m
Ω
> 42 A A
C
11
15 s
Insulation
resistance
9
R
IN
s
10
…
999 k
Ω
1 k
Ω
50
…
500
V DC
1.0 • U
N
…
1.5 • U
N
> 1 mA
< 2 mA
—
—
±
(5% rdg.+ 4 d)
> 10 d
±
(2.5% rdg.+2 d)
> 10 d
264 V
Cont.
1.00
…
9.99 M
Ω
10 k
Ω
10.0
…
99.9 M
Ω
100 k
Ω
≥
20 M
Ω
:
±
(10% rdg.+ 8 d)
≥
20 M
Ω
:
±
(5% rdg.+4 d)
100
…
300 M
Ω
1 M
Ω
Leakage current,
alternative
measurement
2
I
PE
, I
T
, I
E
, I
A
0 ... 99
μ
A
1
μ
A
—
50 ...
250 V~
– 20/+10%
—
< 1.5 mA > 150 k
Ω
1 k
Ω
±
10
Ω
±
(5% rdg.+ 4 d) > 10 d
> 15 mA:
±
(10% rdg.+ 8 d)
±
(2% rdg.+2 d) > 10 d
> 15 mA:
±
(5% rdg.+ 4 d)
264 V
Cont.
100 ... 999
μ
A
1
μ
A
1.00 ... 9.99 mA
10
μ
A
10.0 ... 30.0 mA
100
μ
A
Leakage current,
direct measure-
ment
3
I
PE
, I
T
, I
E
, I
A
, I
P
,
I
PA
Only I
P
, I
PA
: 0.0 ...
99.9
μ
A
100 nA
—
—
—
—
1 k
Ω
±
10
Ω
1 k
Ω
±
(5% rdg.+ 10 d)
> 10 d
±
(2.5% rdg. + 5 d)
> 10 d
264 V
Cont.
0 ... 99
μ
A
1
μ
A
±
(5% rdg.+ 4 d)
> 10 d
±
(2.5% rdg.+ 2 d)
> 10 d
100 ... 999
μ
A
1
μ
A
1.00 ... 9.99 mA
10
μ
A
10.0 ... 30.0 mA
100
μ
A
Leakage current,
differential cur-
rent measure-
ment
4
I
PE
, I
T
, I
E
0 ... 99
μ
A
1
μ
A
—
—
—
—
—
—
±
(5% rdg.+ 10d) > 10 d
±
(2.5% rdg.+2 d)
> 10 d
264 V
Cont.
100 ... 999
μ
A
1
μ
A
±
(5% rdg.+ 4 d)
1.00 ... 9.99 mA
10
μ
A
10.0 ... 30.0 mA
100
μ
A
Fu
n
ction test at the t
e
st sock
et
Line voltage
U
L–N
10
100.0
…
240.0 V
~
0.1 V
—
—
—
—
—
—
—
±
(2% rdg.+2 d)
264 V
Cont.
Load current I
L
0
…
16.00 A
RMS
10 mA
—
—
—
—
—
—
—
±
(2% rdg.+2 d)
16 A
Cont.
Active power P
0
…
3700 W
1 W
—
—
—
—
—
—
—
±
(5% rdg.+10 d)
> 20 d
264 V
Cont.
20 A
10 min.
Apparent power S
0
…
4000 VA
1 VA
Calculated value, U
L–N
• I
V
±
(5% rdg.+10 d)
> 20 d
264 V
Cont.
Power factor PF
with sinusoidal
waveform: cos
ϕ
0.00
…
1.00
0.01
Calculated value, P / S, display > 10 W
±
(10% rdg.+5 d)
264 V
Cont.
Line frequency f
0 ... 420.0 Hz
0.1 Hz
—
—
—
—
—
—
—
±
(2% rdg.+2 d)
264 V
Cont.
t
A
PRCD
Time to Trip
0.1 ... 999 ms
0.1 ms
—
—
30 mA
—
—
—
±
5 ms
—
264 V
Cont.
Vo
lt
age me
asur
eme
n
t
Probe voltage
(probe P1 to PE)
,
and
0.0 ... 99.9 V
100 ... 264 V
100 mV
1 V
—
—
—
—
3 M
Ω
—
—
±
(2% rdg.+2 d)
264 V
Cont.
Measuring voltage
(V-COM
sockets
6
)
,
and
0.0 ... 99.9 V
100 ... 300 V
1 M
Ω
±
(2% rdg.+2 d)
> 45 Hz ... 65 Hz
±
(2% rdg.+5 d)
> 65 Hz ... 10 kHz
±
(5% rdg.+5 d)
> 10 kHz ... 20 kHz
300 V
,
and
I
Leaka
ge
Leakage current
via AT3-IIIE
adapter Z745S
6, 8
0.00 ... 0.99 mA
0.01 mA
—
—
—
—
—
—
—
±
(2% rdg.+2 d)
> 10 d
without adapter
253 V
Cont.
1.0 ... 9.9 mA
0.1 mA
10 ... 20 mA
1 mA
Temp
Temperature
with Pt100 sensor
– 200.0 ...
+850.0
°
C
0.1
°
C
—
< 20 V –
1.1 mA
—
—
—
±
(2% rdg.+1
°
C)
10 V
Cont.
Temperature
with Pt1000
sensor
– 150.0 ...
+850.0
°
C
Содержание SECULIFE ST PRO