R
EVISION
:
-
D
ATE
:
12/29/04
P
AGE
:
6
Copyright
2004 Glasair Aviation, LLC Arlington, Washington All rights reserved
NOTE
In the event of any discrepancy between the limitations given
in this manual and those given in the engine manufacturer’s
operating manual, the latter shall be observed. The pilot should
be thoroughly familiar with the engine operating manual, which
may contain additional limitations not discussed below.
2-4.2 O
IL
P
RESSURE
Lycoming O-360:
Normal Operating.................................................................... 60–90 p.s.i.
Idling ................................................................................................25 p.s.i
Start and Warm-up Maximum (red line) ..................................... 100 p.s.i.
Green Arc ................................................................................ 60–90 p.s.i.
2-4.3 O
IL
T
EMPERATURE
Lycoming O-360:
Recommended .......................................................................82°C/180°F
Maximum (red line)..............................................................118°C/245°F
Green Arc ....................................................... 60°–104°C/140°–220°F
Yellow Arc .........................................................38°–60°C/100°–140°F