USER MANUAL
POSITION CONTROLLER THESI 310
MT02_A37_A_TH310_GIVI_ENG rev. E
Pag. 4/44
W A R N I N G !
It is forbidden to switch on the instrument unless the machine on which it
is installed conforms to 2006/42/EC Directive.
All of the equipments connected to the instrument must have insulation
characteristics in compliance with the regulations in force.
The instrument can be installed only by specialized personnel, following
the instructions provided by the Manufacturer.
It is strictly forbidden to intervene on the instrument while it is powered.
POWER SUPPLY
From 90 Vac to 230 Vac
±
10% - 50/60 Hz or, alternatively,
24 Vac
±
10% - 50/60 Hz (by means of selector). We recommend the
use of a mains power supply provided with an input filter. The power
distribution network to which the instrument is connected must be
equipped with a sectioning device in compliance with the regulations in
force, positioned closed to the instrument.
GROUNDING
The instrument is connected to the ground through the power supply
terminal block. To avoid discharges, we recommend the use of a
socket with a grounding connection. In case of inadequate grounding
connections, all the accessible parts, including those apparently
protected, may generate electrical discharges.
FUSES
Unplug or completely disconnect the power supply before changing
the fuses connected to the terminal block in the rear panel. Use only
delay fuses ø5x20 mm 500 mA 250 V.
PREVENTION
To avoid fires or explosions, this instrument should not be used in the
presence of inflammable gases, solvents, explosives, etc.
REAR PANEL
It can be removed only by specialized personnel, after disconnecting
the power supply.
INSTALLATION
The measuring systems (optical scale, rotary encoder, etc.) must be
installed following the instructions provided by the Manufacturer. Start
connecting the inputs and outputs. At the end, proceed with the power
supply connection.
CATEGORY
Installation category II as per Standard EN 61010-1.
INSTALLATION