USER MANUAL
POSITION CONTROLLER THESI 310
MT02_A37_A_TH310_GIVI_ENG rev. E
Pag. 24/44
Parameter 22
– SETTING OF SLOW MOVEMENT ± 10 V OUTPUT PERCENTAGE
With this parameter it is possible to set the percentage value to be applied on the ± 10 V
output (optional) for the axis movement at low speed. The value is applied both in positive
and negative direction.
Example of value setting = 30 %
P 22
Press
to select the parameter
(see PARAM. SELECTION)
0 0
P 22
Press
to confirm the selection and
enter its settings
0 0 0 0 0 0*
Enter the desired value and align it to the decimal point displayed.
P 22
Press
to confirm the value and go back
to parameters selection
3 0
Press
to quit configuration and go back
to the position display
2 0 0.0
Parameter 23
– SETTING OF FAST MOVEMENT ± 10 V OUTPUT PERCENTAGE
With this parameter it is possible to set the percentage value to be applied on the ± 10 V
output (optional) for the axis movement at high speed. The value is applied both in positive
and negative direction.
Example of value setting = 100 %
P 23
Press
to select the parameter
(see PARAM. SELECTION)
0 0
P 23
Press
to confirm the selection and
enter its settings
0 0 0 0 0 0*
Enter the desired value and align it to the decimal point displayed.
P 23
Press
to confirm the value and go back
to parameters selection
1 0 0
Press
to quit configuration and go back
to the position display
2 0 0.0