USER MANUAL
POSITION CONTROLLER THESI 310
MT02_A37_A_TH310_GIVI_ENG rev. E
Pag. 16/44
Parameter 06
– AXIS RESOLUTION
This parameter allows to select the axis resolution, based on the number of pulses of the
encoder (PPR).
The resolutions that can be set are: 200 – 100 – 50 – 20 – 10 – 5 – 2 – 1 µm
or: 0.01 – 0.005 – 0.002 – 0.001 – 0.0005 – 0.0002 – 0.0001 – 0.00005 inch
Example: selecting 10 µm
P 06
Press
to select the parameter
(see PARAM. SELECTION)
0.1
P 06
Press
to confirm the selection and
enter its settings
0.1*
P 06
Press
to select the desired encoder
resolution
0.0 1*
P 06
Press
to confirm and go back to
parameters selection
0.0 1
Press
to quit configuration and go back
to the position display
2 0 0.0
Parameter 07
– SETTING OF MINIMUM MEASURING LENGTH LIMIT
With this parameter, it is possible to set the position of the minimum measuring length
limit, beyond which the machine will not execute movements.
Example of value setting = -50.0 mm
P 07
Press
to select the parameter
(see PARAM. SELECTION)
0.0
P 07
Press
to confirm the selection and
enter its settings
0 0 0 0 0.0*
P 07
Press
to set a value with negative sign
- 0 0 0 0 0.0*
Enter the desired value and align it to the decimal point displayed.
P 07
Press
to confirm the value and go back
to parameters selection
- 5 0.0