USER MANUAL
POSITION CONTROLLER THESI 310
MT02_A37_A_TH310_GIVI_ENG rev. E
Pag. 25/44
Parameter 24
– MM/INCH CONVERSION
This parameter allows to convert mm in inches.
Example of inch setting
P 24
Press
to select the parameter
(see PARAM. SELECTION)
M i L L
P 24
Press
to confirm the selection and
enter its settings
M i L L *
P 24
Press
to select inch
I n c h *
P 24
Press
to confirm and go back to
parameters selection
I n c h
Press
to quit configuration and go back
to the position display
7.9
Parameter 25
– SELECTING “POSITION WITH ACC./DEC. RAMPS” OPTION
This parameter allows to enable/disable the possibility of positioning the axis (option:
instrument with ± 10 V analog output), using acceleration and deceleration ramps.
Example of selection: enabling
P 25
Press
to select the parameter
(see PARAM. SELECTION)
n o
P 25
Press
to confirm the selection and
enter its settings
n o*
P 25
Press
to choose the desired selection
y E S*
P 25
Press
to confirm and go back to
parameters selection
y E S
Press
to quit configuration and go back
to the position display
2 0 0.0