USER MANUAL
POSITION CONTROLLER THESI 310
MT02_A37_A_TH310_GIVI_ENG rev. E
Pag. 20/44
Press
to quit configuration and go back
to the position display
2 0 0.0
Parameter 14
– SETTING OF POSITIONING TOLERANCE VALUE
With this parameter it is possible to set the tolerance value within which positioning is
accepted.
Example of value setting = 0.1 mm
P 14
Press
to select the parameter
(see PARAM. SELECTION)
0.0
P 14
Press
to confirm the selection and
enter its settings
0 0 0 0 0.0*
Enter the desired value and align it to the decimal point displayed.
P 14
Press
to confirm the value and go back
to parameters selection
0.1
Press
to quit configuration and go back
to the position display
2 0 0.0
Parameter 15
– SETTING OF DEVIATION VALUE
With this parameter, it is possible to set the position deviation value to be applied at the
closure of the related input.
Example of value setting = 5.5 mm
P 15
Press
to select the parameter
(see PARAM. SELECTION)
0.0
P 15
Press
to confirm the selection and
enter its settings
0 0 0 0 0.0*
Enter the desired value and align it to the decimal point displayed.
P 15
Press
to confirm the value and go back
to parameters selection
5.5
Press
to quit configuration and go back
to the position display
2 0 0.0