USER MANUAL
POSITION CONTROLLER THESI 310
MT02_A37_A_TH310_GIVI_ENG rev. E
Pag. 13/44
All the settings for the configuration of the position controller are described below:
Parameter 01
– POSITION PRESET
The parameter is used to set the real position of the axis.
Example of value setting = 200.0 mm
P 01
Press
to select the parameter
(see PARAM. SELECTION)
1 2 0.0
P 01
Press
to confirm the selection and
enter its settings
0 0 0 0 0.0*
Enter the desired value and align it to the decimal point displayed.
P 01
Press
to confirm the value and go back
to parameters selection
2 0 0.0
Press
to quit configuration and go back
to the position display
2 0 0.0
Parameter 02
– INVERSION OF COUNTING DIRECTION
With this parameter it is possible to invert the counting direction of the axis.
Example: inverting counting direction
P 02
Press
to select the parameter
(see PARAM. SELECTION)
d i r -
P 02
Press
to confirm the selection and
enter its settings
d i r -*
P 02
Press
to invert the counting direction
- d i r *
P 02
Press
to confirm and go back to
parameters selection
- d i r
Press
to quit configuration and go back
to the position display
2 0 0.0