USER MANUAL
POSITION CONTROLLER THESI 310
MT02_A37_A_TH310_GIVI_ENG rev. E
Pag. 38/44
Press
to quit automatic operation
and go back to manual
operation
5 0 0.0
Notes:
1) Before running a program, it is possible to display its cycles. Once the desired program
number has been entered, use the SELECTION key to display the position of the first
cycle.
2) During the display of the program’s cycles, it is possible to display the number of the
programmed repetitions. After positioning on the desired cycle, press the ENTER key.
3) A program can be run starting from any of its cycles. Once the number of the program
has been entered, display the desired cycle and press START to execute it.
4) The same program can be run continuously. Once the program has been started, press
the AUTO key and the led will flash. In this way, at the end of the repetitions counting of
the last cycle, the program will automatically resume from the first cycle.
5) To terminate the program, press the STOP key; the cycle/program displays will flash to
signal the interruption.
Press the START key to resume the execution or press the STOP key again to go back
to the programs selection.