TROUBLESHOOTING
Gentherm Global Power Technologi
es
Page 64
TROUBLESHOOTING,
continued
Problem
Probable Cause
Possible Solution
Lookup Section
Low output
power or low
voltage
V
set
adjustment
incorrect
Determine required V
set
for present ambient
temperature at site and
adjust
Power Output
Evaluation and
Adjustment
Airflow past cooling
fins insufficient
Clean the cooling fins of
any debris
Maintenance
Fuel filter dirty
Drain the regulator
sediment bowl
Maintenance
Fuel orifice plugged
Replace the fuel orifice
Maintenance
Fuel orifice size
incorrect
Replace the orifice
Maintenance
Fuel pressure
adjustment incorrect
Adjust TEG fuel manifold
pressure
Adjustment
Safety SOV valve
malfunctioning
Check the safety SOV
valve
Maintenance
Air filter dirty
Clean the air filter
Maintenance
Air-shutter adjustment
incorrect
Adjust air-shutter
Adjustment
C/L* damaged
Examine the C/L
Maintenance
C/L* adjustment
incorrect
Adjust the C/L
Adjustment
Power unit damaged Examine the power unit
Maintenance
Output power
is too high
Fuel pressure
adjustment incorrect
Adjust the TEG fuel
manifold pressure
Adjustment
Output
voltage is too
high
L/C* damaged
Adjust the L/C
Adjustment
L/C* adjustment
incorrect
Adjust the L/C
Adjustment
*applicable for L/C option only