ADJUSTMENT
Gentherm Global Power Technologi
es
Page 48
8.4.1.1
Series Wiring
Series connection is achieved by connecting the 300 W resistor in series with the customer
load as shown with the dark line. The maximum allowable power may be delivered to the CP
load by moving the tap to the bottom of the resistor. To reduce power to the CP load, slide
the tap upward.
8.4.1.2
Parallel Wiring
Parallel connection is achieved by connecting the 300 W resistor in parallel with the customer
load as shown with the dark line, smaller levels of power may be delivered to the CP load.
This may be required when hot spots occur on the anode of the CP circuit. With the tap
located at the top of the resistor the output power will be zero. As the tap is moved down,
the power to the CP load is increased.
Change from a series to parallel configuration by moving the wire running from the top of
the 300 W resistor from the center terminal of the heavy-duty terminal block to the left
terminal.
8.5
ADJUSTMENT OF THE OPTIONAL REMOTE START SYSTEM (TEG
CONTROLLER)
The TEG Controller has an on-board 3 digit 7-segment display. It is used to display measured
values as well as adjust some variables.
8.5.1
Measurement Display on TEG Controller
1.
Press S5 (Display) button to enter the Display mode. Each press of the Display but-
ton toggles through the available measurements, the corresponding indicator above
the display will turn on.
2.
Press the Display button until the display goes off to exit the Display mode. It will also
automatically timeout and exit Display mode.
NOTE:
The Adjustment mode is not available until the Display mode is exited.
8.5.2
Adjustments on the TEG Controller
1.
Press S6 (Adjust) button to enter the Adjustment mode. Each press of the Adjustment
button toggles through the available variables, the corresponding indicator above the
display will turn blink.
2.
Press the S7 (Up) or (S8) Down to make changes to the variable.
3.
Press the Adjust button until the display goes off to exit the Adjustment mode. It will
also automatically timeout and exit Adjustment mode. All variable changes are saved
upon exit of the Adjust mode.
NOTE:
The Adjustment mode is not available until the Display mode is exited.