![Gentherm P-5100 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/gentherm/p-5100/p-5100_operating-manual_2213788056.webp)
MAINTENANCE
Gentherm Global Power Technologi
es
Page 49
9
MAINTENANCE
This section describes how to maintain the model P-5100 TEG. Before attempting to maintain
the TEG the qualified service person should be thoroughly familiar with its:
•
technical specifications;
•
process description;
•
installation;
•
startup and shutdown;
•
power output evaluation, and
•
adjustment.
NOTE:
Good record keeping is necessary for long term follow-up. Use the TEG
Performance Log, located at the end of this manual, for recording details each
time adjustments are made, or servicing is carried out.
9.1
RECOMMENDED PERIODIC MAINTENANCE
The TEG is a solid-state high-reliability device that requires very little maintenance. However,
it does require periodic service checks to provide the years of trouble free service of which it
is capable. The maintenance interval depends on the site conditions (fuel purity,
environment, etc.) and must be established based on-site records. Field experience indicates
that a properly installed TEG usually requires maintenance only once a year.
At least once a year evaluate V
set
as per the procedure below. This should be the first
procedure during any service visit and will determine what further service may be needed.
9.1.1
Tools and Parts Recommended for Routine Servicing
The following tools and parts should be available for routine servicing:
•
1 Multi-meter, including DC voltmeter accurate to ± 0.1 V (and Ohmmeter*).
•
1 Flat-head screwdriver.
•
1 Phillips screwdriver.
•
1 Wrench, 9/16 in.
•
1 Wrench, 1/2 in.
•
1 Wrench, 3/8 in.
•
1 Adjustable wrench, that will open to 16 mm (5/8 in.).
•
1 Fuel filter kit, part number 22363.
•
1 Fuel orifice: for natural gas service use orifice #8 (part number 690), for high BTU
natural gas use orifice #10 (part number 6251), for propane service use orifice#7
(part number 689).
•
1 Battery 6V, 5.0 Ahr, Monoblock, part number 24559*.
•
A combustion analyzer capable of measuring COppm and either CO
2
percentage, or O
2
percentage*