![Gentherm P-5100 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/gentherm/p-5100/p-5100_operating-manual_2213788013.webp)
TECHNICAL SPECIFICATIONS
Gentherm Global Power Technologies
Page 6
Power output
Power Ratings at the beginning of life,
20º C, 750 m above sea level
available at
the terminal strip including reverse
current diode.
100 Watts @ 14.1 Volts
100 Watts @ 28 Volts
Electrical
Adjustment
12 V 12
–
18 Volts
24 V 24-30 Volts
Reverse Current Protection
Yes, diode board is standard.
Output
Terminal block which accepts up to 8
AWG wire. Opening for 3/4” con
duit in the
base of the cabinet
Fuel
Natural Gas
9.4 m
3
/day (332 ft
3
/day) of Std. 1000
BTU / SCF (37.7 MJ/Sm
3
) gas
High BTU Natural Gas
6.3 m
3
/day (222 ft
3
/day) of 1500
BTU / SCF (56.5 MJ/Sm
3
) gas
7.8 m
3
/day (277 ft
3
/day) of 1200
BTU / SCF (45.2 MJ/Sm
3
) gas
Propane
13.8 L/day (3.6 gal/day)
Maximum Supply Pressure
344 kPa (50 psig)
Minimum Supply Pressure
103 kPa (15 psig)
Fuel Connection
1/4”
MNPT
Environmental
Ambient Operating Temperature
Continuously Running TEG
Max. 55º C (130º F) Min. -40º C (-40 ºF)
Operating Conditions
Unsheltered Operation
Materials of Construction
Cabinet
304 Stainless Steel
Cooling Type
Natural Convection
Burner
Meeker type, Inconel 600
Fuel System
Brass, Aluminum & Stainless Steel