ADJUSTMENT
Gentherm Global Power Technologi
es
Page 44
Figure 22 - Change in V
set
Versus Fuel Pressure Adjustment
Based on Figure 22 the fuel pressure must then be increased 2.4 kPa (0.35 psig).
Follow these steps to adjust fuel pressure:
1.
Remove the cover on the regulator and loosen the lock nut.
2.
Turn the adjusting screw (clockwise to increase pressure) until the required change
in pressure is obtained.
NOTE:
Consult Data Plate Label Located on Inner Door for Reference Factory Fuel
Pressure.
3.
Wait ten minutes then measure V
set
and record. If the TEG cannot be adjusted to
match required V
set
value,
then a problem exists with one of the TEG’s systems. If
necessary, see Troubleshooting section for guidance.
4.
Tighten the lock nut and replace the cover on the fuel regulator.