INSTALLATION
Gentherm Global Power Technologies
Page 33
NOTE:
Always mount the CP interface system in an upright position and allow the
free flow of air through the unit.
Figure 17
–
CP Installation
5.8.2
TEG Wiring Interconnection
Wire the CP interface system directly to the TEG using the following procedure. Follow these
steps to wire the CP interface system to the TEG:
1.
Check the wiring diagram, Figure 14 or Figure 15 as applicable and choose the
wiring diagram for your application.
2.
Run the CP interface system wires to the TEG as per Figure 14 or Figure 15,
as appropriate, and terminate to TB-1.
5.8.3
Connection of CP Load
Wire the CP load directly to the CP interface system. Feed the CP anode and cathode load
cables into the CP box and terminate.