![Gentherm P-5100 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/gentherm/p-5100/p-5100_operating-manual_2213788022.webp)
PROCESS DESCRIPTION
Gentherm Global Power Technologies
Page 15
Electrical output characteristics are shown in Figure 6. Power peaks in a broad load resistance
range of 0.30-
0.60 Ω. Rated power of 127 W gross is obtained when the power unit load
resistance is within this range, at the beginning of the service life of the TEG.
Figure 6
–
Model P-5100 Power Unit Electrical Output Characteristics
4.1.5
Cooling Fins and Fin Duct
Cooling of the thermopile is done by the free movement of ambient air through the cooling
fins. A fin duct acts as a chimney, causing ambient air to rise through the cooling fins, thus
helping transfer heat away from the thermopile.
CAUTION!
Keep cooling fins clean and duct work inlets and
outlets clear of obstructions. Restricting the free flow
of cooling air may cause damage to the power unit.
4.1.6
Cabinet
The power unit, burner and fuel system are enclosed in a stainless-steel cabinet.
WARNING!
Surface temperatures of the burner components may
be greater than 100°C.