![Gentherm P-5100 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/gentherm/p-5100/p-5100_operating-manual_2213788015.webp)
TECHNICAL SPECIFICATIONS
Gentherm Global Power Technologies
Page 8
3.4
SYSTEM
The following table gives the technical specifications for the SI system.
Electrical SI
Power
Supply
Input Voltage
Minimum 5.5 V DC
Maximum 35.0 V DC
Power Input
8 Watts
Output Voltage
14.0 VDC
SI
Spark Rate
10/second
Trial for Ignition
7 seconds
Number of tries for
Ignition
3 trials until lockout
Inter-Purge Time
10 seconds
Spark Gap
Nominal
4.8 mm (0.19 in.)
Minimum
3.3 mm (0.13 in.)
Maximum
6.3 mm (0.25 in.)
Continuous Operating Time Without
Charge
120 minutes with full charged 6V, 5 Ah
batteries @ 25ºC (75ºF)
3.5
DATA PLATE
The data plate is on the inside of the cabinet door and includes vital information about the
generator.
Model Number:
The model number on the Data Plate is interpreted as follows:
P-5100 ( ) - ( )
–
( )
–
( )
Fuel Type:
L = Propane
N = Natural Gas
H = High BTU Natural Gas
Output Voltage:
12 or 24 Volts
SS = Stainless Steel Fuel System
CP = Cathodic Protection Interface
RS = Remote Start