Problem
Probable Cause
Possible Solution
Lookup Section
Burner does not
ignite
Air in fuel line
Purge fuel lines of air
Installation
Supply gas pressure
too low
Increase the gas
supply pressure to the
TEG
Installation
Fuel filter dirty
Drain the regulator
sediment
Maintenance
Replace the fuel
filter
Maintenance
Fuel pressure
adjustment incorrect
Adjust the TEG fuel
manifold pressure
Adjustment
Fuel orifice plugged Replace the fuel orifice
Maintenance
Fuel orifice size
incorrect
Replace the fuel orifice
Maintenance
Air filter dirty
Clean the air filter
Maintenance
Air-shutter adjustment
incorrect
Adjust the air-shutter
Adjustment
SI system faulty
Maintain the SI system
Maintenance
Burner will
ignite but will
not continue to
burn
Supply gas pressure
too low
Increase the gas
supply pressure to the
TEG
Installation
Fuel filter dirty
Drain the regulator
sediment bowl.
Maintenance
Replace the fuel filter
Maintenance
Fuel pressure
adjustment incorrect
Adjust the TEG fuel
manifold pressure
Adjustment
Fuel orifice plugged Replace the fuel orifice
Maintenance
Fuel orifice size
incorrect
Replace the orifice with
one of the correct size
Maintenance
Safety SOV valve
malfunctioning
Check the safety SOV
valve
Maintenance
Air filter dirty
Clean the air filter
Maintenance
Air shutter adjustment
incorrect
Adjust the air-shutter
Adjustment