ADJUSTMENT
Gentherm Global Power Technologi
es
Page 41
8.1
POWER OUTPUT ADJUSTMENT
TEG output power is controlled by the flow of air and fuel into the TEG. Use the following
procedures to adjust the TEG’s power output in sequence given.
8.1.1
Adjustment for Elevation
Confirm the fuel gauge pressure is near to the pressure indicated on the data plate located
on the inside of the cabinet doors. If the TEG is located at a different altitude than the factory,
792 m (2600 ft.), the fuel pressure will need to be different to obtain the same results also
be different. Use Figure 20 to determine how much to adjust the fuel pressure.
Example:
If the site elevation is 1000m (3281ft.) then 2.5 kPa (0.36 psig) must be added
to the pressure on the data plate.
Figure 21 - Change in V
set
Versus Air-Shutter Adjustment
Follow these steps to adjust fuel pressure:
1.
Remove the cover on the regulator and loosen the lock nut.
2.
Turn the adjusting screw (clockwise to increase pressure) until the required change
in pressure is obtained.