MAINTENANCE
Gentherm Global Power Technologi
es
Page 55
9.3.2
Inspection of Burner Components
Burner internals are maintenance free for most applications. If the required V
set
still cannot
be achieved after servicing the fuel system, air filter and checking the cooling fins and air
duct then it may be necessary to check and service the burner internals. The procedures
below give the steps for inspecting the burner components
.
Figure 26 - Burner Assembly Cross Section
Follow these steps to remove the burner:
1.
Shut-off the fuel supply to the TEG and allow to cool.
WARNING!
If TEG has not cooled sufficiently it can be very hot.
2.
Disconnect the supply fuel line and fuel inlet valve.
3.
Disconnect the solenoid wire terminal connection and the orange wire connections of
the pressure switch electrical connections.
4.
Remove fuel line between the solenoid valve and orifice fitting.
5.
Remove the 2 bolts mounting the fuel regulator to the cabinet wall and remove the
fuel system.
6.
Remove the 2 screws from each side of the cabinet baffle and remove baffle from
cabinet.