This Maintenance Interval Chart was developed to match the Service chapter of this manual. Detailed information
on each Service Procedure may be found in the Service chapter. A Maintenance Log follow the Interval Chart for
recording the Maintenenace Procedures performed. Recording the 10 Hour (or Daily) service intervals would be
impractical and is therefore not recommended.
NOTE:
Under extreme operating conditions more frequent service than the recommended intervals
may be required. You must decide if your actual operation requires more frequent service based on your
use.
Chapter 11
MAINTENANCE
SERVICE PROCEDURE
Every 10
Every 40
Every 100
Hours
Hours
Hours
(or Daily
(or Weekly)
Check Fuel Tank Level
z
Check Fuel Filter
z
Check Engine Oil
z
Check Air Intake Screen/Coolant Fins (1639)
z
Check Radiator Coolant Level (1649)
z
Check Fan Belt Tension (1649)
z
Check Instruments Operation
z
Check General Machine Operation & Condition
z
Check Air Filter Element
z
Lubricate Appropriate Grease Points
z
z
Change Engine Oil & Filter -
initial 50 hours
z
Check Hydraulic Oil Level
z
Check Crankcase Breather Cap (1639 only)
z
Check Battery
z
Clean Air Filter Element
(Change after two cleanings)
z
Clean Fuel Sediment Bowl (1639)
z
Check Screed Bottom Plate Wear
z
Change Hydraulic Filter Elements
z
MAINTENANCE INTERVAL CHART
907389/AP297
62
Printed In U.S.A.
Discount-Equipment.com
Содержание PowerBox 1639
Страница 13: ...SAFETY Continued Printed In U S A 13 907389 AP297 D i s c o u n t E q u i p m e n t c o m...
Страница 14: ...SAFETY Continued 907389 AP297 14 Printed In U S A D i s c o u n t E q u i p m e n t c o m...
Страница 54: ...1639 Electrical Schematic 907389 AP297 56 Printed In U S A D i s c o u n t E q u i p m e n t c o m...
Страница 55: ...1649 Electrical Schematic Printed In U S A 57 907389 AP297 D i s c o u n t E q u i p m e n t c o m...
Страница 65: ...INTERNATIONAL SYMBOLS D i s c o u n t E q u i p m e n t c o m...