Section 1 — Introduction
5
Only use an approved power adapter — 12 V 3 A
output, center positive. Do NOT use the plug-pack
transformers supplied with previous instrument
versions. Doing so will damage these transformers.
The cover over the comms and charger connectors
provides an essential seal. The cover must be in place
whenever you use the instrument in an industrial
environment.
Failure to comply with this
requirement might void your warranty
. IP65 rating
only applies while the cover is securely in place.
Transfer information stored in the instrument to a PC
before reprogramming (PROFLASHING) the instrument
with new firmware. PROFLASHING the instrument will
delete all stored information.
To obtain accurate measurements, ensure the drive
current is switched on when using an IEPE/ICP®-type
accelerometer.
Mount the sensor correctly before taking
measurements. This will ensure your readings are
accurate and consistent.
Use a mild detergent diluted with warm water to
clean your instrument. Do NOT use abrasive or
polishing substances, hydrocarbons, petrochemicals,
or solvents, as these will degrade the plastic casing.
Do NOT place the instrument or magnetic mounting
base where the temperature might exceed 140°F
(60°C). This will degrade the battery pack and magnet.
If your instrument malfunctions, return it to an
authorized dealer. Do NOT attempt to repair the
instrument yourself as
this will void your warranty
.
Содержание SCOUT100-Ex
Страница 1: ...SCOUT vbSeries Instrument Reference Guide SCOUT100 Ex SCOUT140 Ex vb5 vb6 vb7 vb8 25 September 2014 ...
Страница 18: ...Section 1 Introduction 7 Installation Control Drawing for Hazardous Locations ...
Страница 20: ...Section 1 Introduction 9 Installation Control Drawing GE2214VBX for ATEX Hazardous Locations ...
Страница 21: ...Section 1 Introduction 10 IECEx ATEX Declaration of Conformity ...
Страница 40: ...Section 2 Instrument Fundamentals 29 Viewing hint labels Accessing more detailed help ...
Страница 44: ...Section 2 Instrument Fundamentals 33 Using the advanced options ...
Страница 54: ...Section 3 Sensors 43 Selecting the appropriate voltage for your tachometer and machine ...
Страница 85: ...Section 4 Measurement Types and their Uses 74 Selecting the required parameter settings ...
Страница 111: ...Section 4 Measurement Types and their Uses 100 Using the keypad to enter measurements ...
Страница 116: ...Section 4 Measurement Types and their Uses 105 Example of tracked measurement ...
Страница 120: ...Section 4 Measurement Types and their Uses 109 Saving multi channel measurements ...
Страница 124: ...Section 5 Set Measurement Options 113 Spectral lines submenu ...
Страница 164: ...Section 8 Send and Receive Information 153 Transferring recordings to Ascent ...
Страница 175: ...Section 8 Send and Receive Information 164 Selecting your Wi Fi region Creating a Wi Fi connection ...
Страница 194: ...Section 9 Working with Routes 183 Linear Speed ...
Страница 241: ...Section 11 Balancing Rotors 230 Splitting a weight ...
Страница 247: ...Section 12 Balancing Walkthrough 236 Taking an initial reading ...