Section 9 — Working with Routes
175
View Alarm Bands Configured in Ascent
You can view Alarm Bands configured in Ascent when you review the
measurements on your instrument. To do this:
1.
Press
or
Record Review
on the main menu.
2.
Use the arrow keys on the left to select a recording for review.
3.
Press
Expand Navigator
repeatedly to expand a machine until
its locations and parameter sets display.
NOTE: When you select a parameter set, its associated recordings
will display in the Review column. The newest recording is
highlighted at the top of the column.
4.
Press
Review Selected Recording
.
5.
Press
> Press
Extended Commands.
6.
Use keys
and
to scroll down the list of available options >
Select
Alarm Bands
.
7.
Press
— The Alarm Band or Bands associated with the
measurement will display. The alarm name will be listed, followed by
the:
•
Measurement type the alarm applies to (Spectrum, Waveform,
Demod Spectrum, etc.),
•
Frequency range covered by the alarm in Orders or Hz/CPM.
•
Alarm type (Peak or Power).
EG: Bearing Frequencies (Spectrum) 500Hz - 900Hz (Power)
indicates that the schedule entry includes an alarm named
Bearing Frequencies. This alarm applies to spectra between 500
and 900 Hz. It is checked against measurement Power values (i.e.
the overall RMS value rather than the highest absolute peak in the
frequency range).
NOTE: When you take a measurement that exceeds the alarm
band thresholds configured in Ascent, an alert notification will
display on the instrument above the chart display.
Содержание SCOUT100-Ex
Страница 1: ...SCOUT vbSeries Instrument Reference Guide SCOUT100 Ex SCOUT140 Ex vb5 vb6 vb7 vb8 25 September 2014 ...
Страница 18: ...Section 1 Introduction 7 Installation Control Drawing for Hazardous Locations ...
Страница 20: ...Section 1 Introduction 9 Installation Control Drawing GE2214VBX for ATEX Hazardous Locations ...
Страница 21: ...Section 1 Introduction 10 IECEx ATEX Declaration of Conformity ...
Страница 40: ...Section 2 Instrument Fundamentals 29 Viewing hint labels Accessing more detailed help ...
Страница 44: ...Section 2 Instrument Fundamentals 33 Using the advanced options ...
Страница 54: ...Section 3 Sensors 43 Selecting the appropriate voltage for your tachometer and machine ...
Страница 85: ...Section 4 Measurement Types and their Uses 74 Selecting the required parameter settings ...
Страница 111: ...Section 4 Measurement Types and their Uses 100 Using the keypad to enter measurements ...
Страница 116: ...Section 4 Measurement Types and their Uses 105 Example of tracked measurement ...
Страница 120: ...Section 4 Measurement Types and their Uses 109 Saving multi channel measurements ...
Страница 124: ...Section 5 Set Measurement Options 113 Spectral lines submenu ...
Страница 164: ...Section 8 Send and Receive Information 153 Transferring recordings to Ascent ...
Страница 175: ...Section 8 Send and Receive Information 164 Selecting your Wi Fi region Creating a Wi Fi connection ...
Страница 194: ...Section 9 Working with Routes 183 Linear Speed ...
Страница 241: ...Section 11 Balancing Rotors 230 Splitting a weight ...
Страница 247: ...Section 12 Balancing Walkthrough 236 Taking an initial reading ...