![GE PanaFlow HT Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/ge/panaflow-ht/panaflow-ht_user-manual_128416121.webp)
Appendix C. Modbus Map
112
PanaFlow HT User’s Manual
Register
(in Hex)
Register (in
Decimal)
Access
Level
Variable
Unit Group
Read Only/
Read Write
Format
8608
34312
VIEWER
Ch_1 DeltaT
19
RO
(IEEE 32 bit)
860A
34314
VIEWER
Ch_1 Time in buffer on Dn channel
19
RO
(IEEE 32 bit)
860C
34316
VIEWER
Ch_1 Up Signal Quality
18
RO
(IEEE 32 bit)
860E
34318
VIEWER
Ch_1 Dn Signal Quality
18
RO
(IEEE 32 bit)
8610
34320
VIEWER
Ch_1 Up Amp Disc
18
RO
(IEEE 32 bit)
8612
34322
VIEWER
Ch_1 Dn Amp Disc
18
RO
(IEEE 32 bit)
8614
34324
VIEWER
Ch_1 Signal Gain Up
3
RO
(IEEE 32 bit)
8616
34326
VIEWER
Ch_1 Signal Gain Down
3
RO
(IEEE 32 bit)
8618
34328
VIEWER
Ch_1_SNR on UP channel
18
RO
(IEEE 32 bit)
861A
34330
VIEWER
Ch_1_SNR on DOWN channel
18
RO
(IEEE 32 bit)
861C
34332
VIEWER
Ch_1 Time in buffer on Up channel
19
RO
(IEEE 32 bit)
Channel 1 Integer - FF Terminal Block 4
8700
34560
VIEWER
Ch_1 status bit map
18
RO
INT32
8702
34562
VIEWER
Ch_1 most significant error (see Error
Tables)
18
RO
INT32
8704
34564
VIEWER
Ch_1 Up +- Peak
18
RO
INT32
8706
34566
VIEWER
Ch_1 Dn +- Peak
18
RO
INT32
8708
34568
VIEWER
Ch_1 dynamic threshold on UP channel 12
RO
INT32
870A
34570
VIEWER
Ch_1 dynamic threshold on DOWN
channel
12
RO
INT32
870C
34572
VIEWER
Ch_1 #Errors of Last 16
18
RO
INT32
Channel 2 Real - FF Terminal Block 5
8A00
35328
VIEWER
Ch_2 Velocity
20
RO
(IEEE 32 bit)
8A02
35330
VIEWER
Ch_2 Sound Speed
20
RO
(IEEE 32 bit)
8A04
35332
VIEWER
Ch_2 Transit Time Up
19
RO
(IEEE 32 bit)
8A06
35334
VIEWER
Ch_2 Transit Time Dn
19
RO
(IEEE 32 bit)
8A08
35336
VIEWER
Ch_2 DeltaT
19
RO
(IEEE 32 bit)
8A0A
35338
VIEWER
Ch_2 Time in buffer on Dn channel
19
RO
(IEEE 32 bit)
8A0C
35340
VIEWER
Ch_2 Up Signal Quality
18
RO
(IEEE 32 bit)
8A0E
35342
VIEWER
Ch_2 Dn Signal Quality
18
RO
(IEEE 32 bit)
8A10
35344
VIEWER
Ch_2 Up Amp Disc
18
RO
(IEEE 32 bit)
8A12
35346
VIEWER
Ch_2 Dn Amp Disc
18
RO
(IEEE 32 bit)
8A14
35348
VIEWER
Ch_2 Signal Gain Up
3
RO
(IEEE 32 bit)
8A16
35350
VIEWER
Ch_2 Signal Gain Down
3
RO
(IEEE 32 bit)
8A18
35352
VIEWER
Ch_2_SNR on UP channel
18
RO
(IEEE 32 bit)
8A1A
35354
VIEWER
Ch_2_SNR on DOWN channel
18
RO
(IEEE 32 bit)
8A1C
35356
VIEWER
Ch_2 Time in buffer on Up channel
19
RO
(IEEE 32 bit)
Channel 2 Integer - FF Terminal Block 5
8B00
35584
VIEWER
Ch_2 status bit map
18
RO
INT32
8B02
35586
VIEWER
Ch_2 most significant error (see Error
Tables)
18
RO
INT32
Table 10: XMIT Modbus Map (cont.)
Содержание PanaFlow HT
Страница 1: ...GE Measurement Control Flow 910 294U Rev A September 2012 PanaFlow HT User s Manual ...
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 14: ...Chapter 1 Introduction 4 PanaFlow HT User s Manual no content intended for this page ...
Страница 84: ...Chapter 3 Initial Setup and Programming 74 PanaFlow HT User s Manual no content intended for this page ...
Страница 98: ...88 PanaFlow HT User s Manual no content intended for this page ...
Страница 99: ...PanaFlow HT User s Manual 89 Appendix B Menu Maps Appendix B Menu Maps ...
Страница 100: ...Appendix B Menu Maps 90 PanaFlow HT User s Manual ...
Страница 137: ...128 PanaFlow HT User s Manual no content intended for this page ...
Страница 142: ...PanaFlow HT User s Manual 133 D 5 Review Menu Figure 39 Review Menu ...
Страница 143: ...134 PanaFlow HT User s Manual no content intended for this page ...
Страница 147: ...138 PanaFlow HT User s Manual no content intended for this page ...
Страница 153: ...144 PanaFlow HT User s Manual no content intended for this page ...
Страница 155: ...146 PanaFlow HT User s Manual no content intended for this page ...
Страница 161: ...Warranty 152 PanaFlow HT Ultrasonic Liquid Flowmeter User s Manual no content intended for this page ...
Страница 162: ......