![GE PanaFlow HT Скачать руководство пользователя страница 118](http://html.mh-extra.com/html/ge/panaflow-ht/panaflow-ht_user-manual_128416118.webp)
PanaFlow HT User’s Manual
109
Appendix C. Modbus Map
Register
(in Hex)
Register (in
Decimal)
Access
Level
Variable
Unit Group
Read Only/
Read Write
Format
812C
33068
SIL USER
Composite Selection for FireLow/ Fire
High during fault: 0: Fire-Low, 1:
Fire-High
18
RW
INT32
812E
33070
SIL USER
Composite Analog Output Selection: 0:
Mass Flow, 1: Actual Volumetric, 2:
Standard Volumetric
18
RW
INT32
8130
33072
SERVICE
Composite Calibration Mode Selection:
0: Off 1: Gate Input, 2: Frequency
Output
18
RW
INT32
8132
33074
SERVICE
Composite Base Frequency for
frequency Output
6
RW
INT32
8134
33076
SERVICE
Composite Span Frequency for
frequency Output
6
RW
INT32
8136
33078
SERVICE
Composite Frequency Output Unit
Selection: 0: Velocity, 1: Volumetric, 2:
Mass Flow
18
RW
INT32
8138
33080
SERVICE
Composite Frequency Output Error
State Selection: 0: Force Low, 1: Force
High, 2: Hold Last
18
RW
INT32
813A
33082
SERVICE
Composite Path Error Handling: 0: Off,
1: On
18
RW
INT32
813C
33084
SIL USER
Composite Unit Type Dimension (see
Unit Table, C.2)
18
RW
INT32
813E
33086
SIL USER
Composite Unit Type Density (see Unit
Table, C.2)
18
RW
INT32
8140
33088
SIL USER
Composite Unit Type Mass Flow (see
Unit Table, C.2)
18
RW
INT32
8142
33090
SIL USER
Composite Unit Type Volumetric (see
Unit Table, C.2)
18
RW
INT32
8144
33092
SIL USER
Composite Unit Type Velocity (see Unit
Table, C.2)
18
RW
INT32
8146
33094
SERVICE
Composite Test Frequency for
Frequency Output
6
RW
INT32
8148
33096
FACTORY
Composite Sensor serial number 3
18
RW
INT32
814A
33098
FACTORY
Composite Sensor serial number 4
18
RW
INT32
814C
33100
FACTORY
Composite Sensor serial number 5
18
RW
INT32
814E
33102
FACTORY
Composite Sensor serial number 6
18
RW
INT32
8150
33104
FACTORY
Composite Flowmeter/System serial
number
18
RW
INT32
8152
33106
SIL USER
Composite Unit Type Time (see Unit
Table, C.2)
18
RW
INT32
8154
33108
SIL USER
Composite Unit Type Viscosity (see
Unit Table, C.2)
18
RW
INT32
8156
33110
SIL USER
Composite Unit Type Standard
Volumetric (see Unit Table, C.2)
18
RW
INT32
8158
33112
FACTORY
Composite Standard BWT buffer 1
serial number
18
RW
INT32
Table 10: XMIT Modbus Map (cont.)
Содержание PanaFlow HT
Страница 1: ...GE Measurement Control Flow 910 294U Rev A September 2012 PanaFlow HT User s Manual ...
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 14: ...Chapter 1 Introduction 4 PanaFlow HT User s Manual no content intended for this page ...
Страница 84: ...Chapter 3 Initial Setup and Programming 74 PanaFlow HT User s Manual no content intended for this page ...
Страница 98: ...88 PanaFlow HT User s Manual no content intended for this page ...
Страница 99: ...PanaFlow HT User s Manual 89 Appendix B Menu Maps Appendix B Menu Maps ...
Страница 100: ...Appendix B Menu Maps 90 PanaFlow HT User s Manual ...
Страница 137: ...128 PanaFlow HT User s Manual no content intended for this page ...
Страница 142: ...PanaFlow HT User s Manual 133 D 5 Review Menu Figure 39 Review Menu ...
Страница 143: ...134 PanaFlow HT User s Manual no content intended for this page ...
Страница 147: ...138 PanaFlow HT User s Manual no content intended for this page ...
Страница 153: ...144 PanaFlow HT User s Manual no content intended for this page ...
Страница 155: ...146 PanaFlow HT User s Manual no content intended for this page ...
Страница 161: ...Warranty 152 PanaFlow HT Ultrasonic Liquid Flowmeter User s Manual no content intended for this page ...
Страница 162: ......