Section 3-5 - Configuration
Use the General tab of the Viewing Properties page to define general properties of the Viewing Section.
•
Initial Settings
-
Annotation level:
Annotation level that is initially used in the Viewing Section.
-
Mask State:
Set how masks are displayed when entering the Viewing Section. The options
NONE, SHOW and ACTIVATE correspond to the radio buttons on the Masks totable in the
Viewing Section.
-
Mask Type:
Set the type of mask that will appear as the default in the drop-down list at the
top of the Masks tool tab in the Viewing Section.
•
Viewing Area
-
Monitor groups:
Specifies the number of monitor groups you configured. Leave the field
blank to have LOGIQworks display on all monitors.
-
Hanging protocol group:
Specifies the group to which you want to apply your hanging
protocols.
-
Navigation buttons:
Click the Config... button to customize where you want to position the
Up, Down, Up Series, Down Series, Previous, Next and Back buttons in the Viewing Section.
-
Display Series from Level:
Select the default that determines how LOGIQworks should fill
the series area of the Viewing Section when you view multiple studies.
*
Select
Patients
if you want to display the first series of each patient when opening
multiple items for viewing.
*
Select
Studies
if you want to display the first series of each study when opening multiple
items for viewing.
*
Select
Series
if you want to display all the series of the first study, and then all the series
of any remaining studies.
-
Show Menu Bar:
Check this check box if you want LOGIQworks to display in the Viewing
Section a menu bar with commands for viewing images.
•
Data
-
Direct View:
LOGIQworks can allow studies that are not immediately available on the local
system (such as those in a remote view) to be “directly viewed”. Such studies will be opened
immediately for viewing and the Pictorial Index will continually update to display new images
as they arrive until all images have been received. To enable this feature, make sure the
Direct View check box is checked and also set a Default Retrieve AE (see below) (Default:
checked).
It could be that you never want your Viewing Section to be updated while viewing studies. You
can turn off the direct viewing of images as they are received by unchecking the Direct View
check box. Note, however, that this will turn off all the features relating to viewing images as
they arrive, such as monitoring mode and directly viewing images from a remote view.
-
Fallback Retrieve AE Title:
The second application title at which LOGIQworks will look to
see where images are if they are not at the location of the primary application entity (machine
hosting the study).
-
Multi Study Save Mode:
This mode determines how changes can be saved to studies during
multi study viewing.
*
All Combined
means that the Save Data dialog box will be displayed only once (when
something has been changed/added and can be saved with the study) and allows all
relevant changes to be saved to the respective studies in a single action.
*
Most Recent Only
means that the Save Data dialog box is only displayed for the most
recent study (determined by study data and time) and not for the other studies.
*
None
means that the Save Data dialog box will never appear in multi-study mode.
*
Sequential
means that the Save Data dialog will be displayed for all studies sequentially.
Содержание H49021AA
Страница 2: ......
Страница 9: ...GE HEALTHCARE DIRECTION 5184024 100 REVISION 5 LOGIQWORKS BASIC SERVICE MANUAL vii ...
Страница 418: ...GE MEDICAL SYSTEMS DIRECTION 5184024 100 REVISION 5 LOGIQWORKS BASIC SERVICE MANUAL II ...
Страница 419: ......