GE Multilin
G60 Generator Protection System
9-3
9 THEORY OF OPERATION
9.1 PHASE DISTANCE THROUGH POWER TRANSFORMERS
9
Table 9–2: PHASE DISTANCE INPUT SIGNALS FOR WYE-DELTA TRANSFORMERS
TRANSFORMER
CONNECTION
LOOP
CURRENT
TRANSFORMATION
VOLTAGE
TRANSFORMATION
Yd1
AB
BC
CA
Yd3
AB
BC
CA
Yd5
AB
BC
CA
Yd7
AB
BC
CA
Yd9
AB
BC
CA
Yd11
AB
BC
CA
I
AB
_21
P
1
3
-------
2
I
A
I
B
–
I
C
–
(
)
=
V
AB
_21
P
3
V
A
=
I
BC
_21
P
1
3
-------
2
I
B
I
A
–
I
C
–
(
)
=
V
BC
_21
P
3
V
B
=
I
CA
_21
P
1
3
-------
2
I
C
I
A
–
I
B
–
(
)
=
V
CA
_21
P
3
V
C
=
I
AB
_21
P
1
3
-------
I
A
I
B
2
I
C
–
+
(
)
=
V
AB
_21
P
3
V
C
–
=
I
BC
_21
P
1
3
-------
I
B
I
C
2
I
A
–
+
(
)
=
V
BC
_21
P
3
V
A
–
=
I
CA
_21
P
1
3
-------
I
A
I
C
2
I
B
–
+
(
)
=
V
CA
_21
P
3
V
B
–
=
I
AB
_21
P
1
3
-------
2
I
B
I
A
–
I
C
–
(
)
=
V
AB
_21
P
3
V
B
=
I
BC
_21
P
1
3
-------
2
I
C
I
A
–
I
B
–
(
)
=
V
BC
_21
P
3
V
C
=
I
CA
_21
P
1
3
-------
2
I
A
I
B
–
I
C
–
(
)
=
V
CA
_21
P
3
V
A
=
I
AB
_21
P
1
3
-------
I
B
I
C
2
I
A
–
+
(
)
=
V
AB
_21
P
3
V
A
–
=
I
BC
_21
P
1
3
-------
I
A
I
C
2
I
B
–
+
(
)
=
V
BC
_21
P
3
V
B
–
=
I
CA
_21
P
1
3
-------
I
A
I
B
2
I
C
–
+
(
)
=
V
CA
_21
P
3
V
C
–
=
I
AB
_21
P
1
3
-------
2
I
C
I
A
–
I
B
–
(
)
=
V
AB
_21
P
3
V
C
=
I
BC
_21
P
1
3
-------
2
I
A
I
B
–
I
C
–
(
)
=
V
BC
_21
P
3
V
A
=
I
CA
_21
P
1
3
-------
2
I
B
I
A
–
I
C
–
(
)
=
V
CA
_21
P
3
V
B
=
I
AB
_21
P
1
3
-------
I
A
I
C
2
I
B
–
+
(
)
=
V
AB
_21
P
3
V
B
–
=
I
BC
_21
P
1
3
-------
I
A
I
B
2
I
C
–
+
(
)
=
V
BC
_21
P
3
V
C
–
=
I
CA
_21
P
1
3
-------
I
B
I
C
2
I
A
–
+
(
)
=
V
CA
_21
P
3
V
A
–
=
Содержание G60 UR Series
Страница 2: ......
Страница 4: ......
Страница 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Страница 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 102: ...3 48 G60 Generator Protection System GE Multilin 3 4 MANAGED ETHERNET SWITCH MODULES 3 HARDWARE 3 ...
Страница 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 446: ...8 18 G60 Generator Protection System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 452: ...9 6 G60 Generator Protection System GE Multilin 9 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 9 THEORY OF OPERATION 9 ...
Страница 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Страница 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Страница 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Страница 634: ...x G60 Generator Protection System GE Multilin INDEX ...