2-2
G60 Generator Protection System
GE Multilin
2.1 INTRODUCTION
2 PRODUCT DESCRIPTION
2
Figure 2–1: SINGLE LINE DIAGRAM
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
FUNCTION
FUNCTION
Breaker control
FlexElements™ (16)
Stator differential
Contact inputs (up to 96)
Generator unbalance
Synchrophasors
Contact outputs (up to 96)
IEC 61850 communications (optional)
Time synchronization over SNTP
Control pushbuttons
Metering: current, voltage, power,
frequency
Transducer inputs and outputs
Data logger
Trip output
Digital counters (8)
Oscillography
User-definable displays
Digital elements (48)
Modbus communications
User-programmable fault reports
Direct inputs and outputs (32)
Modbus user map
User-programmable LEDs
Disconnect switches
Non-volatile latches
User-programmable pushbuttons
DNP 3.0 or IEC 60870-5-104 protocol
Non-volatile selector switch
User-programmable self-tests
Ethernet Global Data protocol (optional)
RTD protection
Virtual inputs (64)
Event recorder
Remote RTD protection
Virtual outputs (96)
FlexLogic™ equations
Setting groups (6)
VT fuse failure
830710AA.CDR
50G
87G
51G
64TN
51P 51N
46
67P
67N
67_2
68
78
24
59P
27P
59_2
25
Metering
Trip
Close
32
50/27
40
59N
81U
81O
27TN
59X
27X
G60 Generator Protection System
52
R
87S
50N
81R
50P
21P
G
49
Содержание G60 UR Series
Страница 2: ......
Страница 4: ......
Страница 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Страница 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 102: ...3 48 G60 Generator Protection System GE Multilin 3 4 MANAGED ETHERNET SWITCH MODULES 3 HARDWARE 3 ...
Страница 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 446: ...8 18 G60 Generator Protection System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 452: ...9 6 G60 Generator Protection System GE Multilin 9 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 9 THEORY OF OPERATION 9 ...
Страница 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Страница 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Страница 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Страница 634: ...x G60 Generator Protection System GE Multilin INDEX ...