CHAPTER 8: AUTOMATION
AUTOMATION LOGIC
D90
PLUS
LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL
487
Figure 423: Maximum operations per hour alarm automation logic
Customizing the automation logic operands
Select the
Settings > Configure FlexOperands
menu item to open the user-configurable
operands window.
Figure 424: User-configurable automation logic operands window
The left side of this screen displays all operands that are currently available to the D90
Plus
.
The automation logic operands are displayed by selecting the
Automation
tree item. Each
operand can be renamed with a user-specified value to provide additional information or
match specific applications.
User Configured Event Name
Range: up to 20 alphanumeric characters
Default: ---
Each available automation operand can be renamed to a user-specified value. This
feature allows users to rename operands to allow for clearer identification or to match
specific applications. The new operand name will appear in protection and automation
logic, in settings that take operands as their value, and in event reports.
Automation logic operands
The following automation logic operands are available for the D90
Plus
. They are listed
alphabetically by operand syntax. The definitions listed below reflect the default operand
names. Some operands can be renamed within their settings window, including the names
of breakers, contact inputs, virtual inputs, and virtual outputs. All operands can also be
assigned user-defined names through the
Settings > Configure FlexOperands
menu item.
Automation virtual output operands
Aut VO 1 ON..................................................Asserted when automation virtual output 1 is in the ON state
(logic 1).
$&'5
$7,0(5
7,0(287$92
7,0(287$92
7,0(28721$92
127
$7,0(5
,1
3.
'3
Содержание D90 Plus
Страница 10: ...x D90PLUS LINE DISTANCE PROTECTION SYSTEM INSTRUCTION MANUAL TABLE OF CONTENTS ...
Страница 438: ...428 D90PLUS LINE DISTANCE PROTECTION SYSTEM INSTRUCTION MANUAL PROTECTION FLEXANALOG PARAMETERS CHAPTER 7 PROTECTION ...
Страница 502: ...492 D90PLUS LINE DISTANCE PROTECTION SYSTEM INSTRUCTION MANUAL AUTOMATION FLEXANALOG PARAMETERS CHAPTER 8 AUTOMATION ...
Страница 626: ...616 D90PLUS LINE DISTANCE PROTECTION SYSTEM INSTRUCTION MANUAL ENERVISTA SECURITY MANAGEMENT SYSTEM CHAPTER 13 SECURITY ...
Страница 678: ...668 D90PLUS LINE DISTANCE PROTECTION SYSTEM INSTRUCTION MANUAL SINGLE POLE TRIPPING CHAPTER 15 THEORY OF OPERATION ...
Страница 684: ...674 D90PLUS LINE DISTANCE PROTECTION SYSTEM INSTRUCTION MANUAL DISPOSAL CHAPTER 16 MAINTENANCE ...
Страница 686: ...676 D90PLUS LINE DISTANCE PROTECTION SYSTEM INSTRUCTION MANUAL REVISION HISTORY CHAPTER 17 APPENDIX ...