Right-side panel
21.
Pulse Rate
window: shows pulse rate in beats per minute.
22. SpO
2
pulse indicator: flashing red LED bar indicates that pulses are being
derived from SpO
2
signals.
23.
SpO
2
window: indicates oxygen saturation in %.
24.
MAP/Cuff
window: indicates measured mean arterial pressure (MAP) in
mmHg and shows cuff pressure during NIBP determination.
25.
ADULT
indicator: lights to indicate you are making a change to adult/ped
NIBP limits or inflation pressure settings.
26.
NEONATE
indicator: lights to indicate you are making a change to neonate
NIBP limits or inflation pressure settings.
27.
AUTO CYCLE
indicator: lights green to indicate auto mode is the chosen
NIBP mode; flashes to indicate you are making a change to the auto mode.
28.
Min
window: displays the NIBP mode if manual or
Stat
as well as the cycle
time when taking auto NIBP determinations.
29.
HISTORY
indicator: flashes to indicate you are in history mode.
30.
BATTERY OK
indicator: lights green to indicate the monitor is operating on
battery power and that the battery is sufficiently charged.
31.
BATTERY LOW
indicator: lights amber to indicate low charge for the battery
(less than 45 minutes when solid; 5 minutes or less when flashing).
32.
CHARGING
indicator: lights green to indicate presence of external power
source and battery charging.
33.
Temperature
window: indicates measured temperature.
Right-side panel
1
Содержание CareScape V100
Страница 9: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 1 1 1 Introduction ...
Страница 25: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 2 1 2 Equipment overview ...
Страница 42: ...2 18 CARESCAPE V100 Vital Signs Monitor 2048723 002C Equipment overview Functional description For your notes ...
Страница 43: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 3 1 3 Installation ...
Страница 59: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 4 1 4 Maintenance ...
Страница 90: ...4 32 CARESCAPE V100 Vital Signs Monitor 2048723 002C Maintenance Test results form ...
Страница 91: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 5 1 5 Troubleshooting ...
Страница 98: ...5 8 CARESCAPE V100 Vital Signs Monitor 2048723 002C Troubleshooting Alarm code interpretation For your notes ...
Страница 99: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 1 6 Parts lists and drawings ...
Страница 127: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 29 Parts lists and drawings Field replaceable units FRUs ...
Страница 128: ...6 30 CARESCAPE V100 Vital Signs Monitor 2048723 002C Parts lists and drawings Field replaceable units FRUs ...
Страница 129: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 31 Parts lists and drawings Field replaceable units FRUs ...
Страница 130: ...6 32 CARESCAPE V100 Vital Signs Monitor 2048723 002C Parts lists and drawings Field replaceable units FRUs ...
Страница 131: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 33 Parts lists and drawings Field replaceable units FRUs ...
Страница 132: ...6 34 CARESCAPE V100 Vital Signs Monitor 2048723 002C Parts lists and drawings Field replaceable units FRUs ...
Страница 133: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 35 Parts lists and drawings Field replaceable units FRUs ...
Страница 145: ...2048723 002C CARESCAPE V100 Vital Signs Monitor A 1 A Technical specifications and default settings ...
Страница 163: ...2048723 002C CARESCAPE V100 Vital Signs Monitor B 1 B Appropriate use of NIBP simulators ...
Страница 177: ......