![GE CareScape V100 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/ge/carescape-v100/carescape-v100_service-manual_128562028.webp)
2-4
CARESCAPE V100 Vital Signs Monitor
2048723-002C
Equipment overview:
Front panel indicators
9.
Cycle
button: used to select NIBP mode of manual, auto cycle, or Stat mode.
10. Temperature probe cover storage: stores Alaris probe covers.
11.
History
button: activates the history mode to view stored patient data. The
most recent entries are displayed first. Press and hold the button for 2
seconds to clear all entries stored.
12.
button: prints currently displayed values or all stored entries when in
history mode.
13.
On/Off
button: controls on/off state of monitor; push for power on and push
again for power off.
14. Alaris temperature probe connector: attach temperature probe cable here.
(The Exergen scanner connects to the host communication port at the back
of the system. Refer to
Front panel indicators
15.
Alarm
silence indicator:
Solid red: Indicates that an alarm silence is active and the audible alarm
tones are silenced for 2 minutes.
Blinking red (Legacy alarm mode only): Indicates that an alarm silence is
not active and at least one alarm condition is present.
16.
Systolic
window: indicates measured systolic NIBP in mmHg.
17.
Diastolic
window: indicates measured diastolic NIBP in mmHg.
18.
INFLATE PRESSURE
indicator: flashes to indicate you are making a change
to the inflation pressure. Adjustable for adult/ped and neonate patients.
19.
ALARM VOLUME
indicator: flashes to indicate you are making a change to
the alarm volume.
20.
PULSE VOLUME
indicator: flashes to indicate you are making a change to
the pulse volume.
HISTORY
AUTO CYCLE
MAP/Cuff
BATTERY
Pulse Rate
Temperature
SpO
C
F
Diastolic
Systolic
ALARM VOLUME
HIGH
HIGH
HIGH
HIGH
LOW
LOW
LOW
LOW
CHARGING
PULSE VOLUME
INFLATE PRESSURE
16
17
18
21
22
23
15
24
25
26
28
28
29
20
19
ADULT
NEONATE
30
31
OK
27
29
30
31
32
33
Содержание CareScape V100
Страница 9: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 1 1 1 Introduction ...
Страница 25: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 2 1 2 Equipment overview ...
Страница 42: ...2 18 CARESCAPE V100 Vital Signs Monitor 2048723 002C Equipment overview Functional description For your notes ...
Страница 43: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 3 1 3 Installation ...
Страница 59: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 4 1 4 Maintenance ...
Страница 90: ...4 32 CARESCAPE V100 Vital Signs Monitor 2048723 002C Maintenance Test results form ...
Страница 91: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 5 1 5 Troubleshooting ...
Страница 98: ...5 8 CARESCAPE V100 Vital Signs Monitor 2048723 002C Troubleshooting Alarm code interpretation For your notes ...
Страница 99: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 1 6 Parts lists and drawings ...
Страница 127: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 29 Parts lists and drawings Field replaceable units FRUs ...
Страница 128: ...6 30 CARESCAPE V100 Vital Signs Monitor 2048723 002C Parts lists and drawings Field replaceable units FRUs ...
Страница 129: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 31 Parts lists and drawings Field replaceable units FRUs ...
Страница 130: ...6 32 CARESCAPE V100 Vital Signs Monitor 2048723 002C Parts lists and drawings Field replaceable units FRUs ...
Страница 131: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 33 Parts lists and drawings Field replaceable units FRUs ...
Страница 132: ...6 34 CARESCAPE V100 Vital Signs Monitor 2048723 002C Parts lists and drawings Field replaceable units FRUs ...
Страница 133: ...2048723 002C CARESCAPE V100 Vital Signs Monitor 6 35 Parts lists and drawings Field replaceable units FRUs ...
Страница 145: ...2048723 002C CARESCAPE V100 Vital Signs Monitor A 1 A Technical specifications and default settings ...
Страница 163: ...2048723 002C CARESCAPE V100 Vital Signs Monitor B 1 B Appropriate use of NIBP simulators ...
Страница 177: ......